<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Archiving and Interchange DTD v1.0 20120330//EN" "JATS-archivearticle1.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink">
  <front>
    <journal-meta />
    <article-meta>
      <title-group>
        <article-title>Industrial Control System: Comprehensive Security Approach</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <string-name>SUPPORT PAPER</string-name>
        </contrib>
      </contrib-group>
    </article-meta>
  </front>
  <body>
    <sec id="sec-1">
      <title>-</title>
      <p>AUTHORS</p>
    </sec>
    <sec id="sec-2">
      <title>1. DESCRIPTION OF THE CYBER THREAT</title>
      <p>The switch to the "Digital Era", characterized by profound dependence on computer systems,
expose the current society to threats that were unthinkable a few decades ago.</p>
      <p>
        While smartphones, tablets, personal computers are tools that allow us to live in an interconnected
global network, changing the concept of time and space and to benefit from entirely new forms of
communications, om the other end these are the breeding ground for attackers that are designed to
steal data, spy on, disrupt and hit their "target" (
        <xref ref-type="bibr" rid="ref1">1</xref>
        ).
      </p>
      <p>
        The threat in cyberspace is becoming an increasingly significant relief and directly proportional to
those countries, including ours, the most technologically advanced basing much of its economy on
Information Technology (
        <xref ref-type="bibr" rid="ref2">2</xref>
        ).
      </p>
      <p>For this reason as just said, developing new capabilities and new tools to improve the cyber
security of the country system is a challenge nationally important for growth , well-being and the
security of citizens. The correlation between the economic prosperity of a nation and the quality of
its cyber infrastructure will be getting tighter and a country to stay in the group of the most
developed and advanced nations, will need to improve cyber security, in the industrial system, in
public administration and most important in the sensibility of the people.</p>
      <p>The cyber-attacks can be conducted by a variety of actors - such as states, organized crime,
political activists, entities without identity - who are able to act in different ways to achieve their
interests and objectives in the most important areas of the country such as political, economic,
social and military.</p>
      <p>
        The events of recent years are showing us that many systems, among which are those defined as
"legacy", designed and implemented mainly to ensure service availability and at the expense of the
safety aspects, have been and are the subject of cyber-attacks daily through the exploitation of
vulnerabilities in the setup procedures, management systems and implementation (
        <xref ref-type="bibr" rid="ref4">3</xref>
        ).
In this context, the cyber threat is increasingly evolving: hackers, using sophisticated and
persistent attack techniques, are targeting, not just the most common communication services,
such as web servers and mail servers, but also the most complex industrial systems such as power
plants and energy distribution, whose failure has a significant impact on both the economic
structure of the country system and the daily lives of its citizens.
Nowadays the circumstances force us to make a fundamental distinction, from the technological
and doctrinal point of view, into two areas: Information Technology (IT) and Operational
Technology (OT).
      </p>
      <p>The IT, Information Technology, is defined as the set of communications, networks and
networking that ensures the management of information between users so they are securely sent,
received and stored.</p>
      <p>
        Information Technology devices are chiefly placed in office spaces or enterprise data center that
are clean and temperature- and humidity-controlled, with either failover systems and/or local
support staff available to respond quickly to performance issues, or both. (
        <xref ref-type="bibr" rid="ref5">4</xref>
        )
The OT, Operational Technology, is instead defined as the set of communications hardware and
software systems, with which can be controlled and supervised the industrial systems, causing or
detecting changes made on these physical systems in real-time or near-real -time. One example is
an energy management system of a dam or a wind power production system.
      </p>
      <p>
        Operational Technology devices are designed to perform a very limited number of functions, often
only one, according to exceedingly high reliability metrics. For example, a temperature
monitoring sensor in a boiler may not be improved by the installation of powerful processor, but
the unfailing performance of its one duty, to consistently and accurately report the temperature, is
an essential link in the chain that keeps the boiler from overheating and exploding. Understanding
this distinction, that reliability and integrity are absolutely the primary considerations, is key to
comprehending the divide between OT and IT, whether we are discussing their cultures, their
organizations, or their technologies. (
        <xref ref-type="bibr" rid="ref5">4</xref>
        )
This distinction immediately highlights the different purpose of these two families of devices, and
consequently their difficult integration, which represents in the modern information warfare one of
the main vectors of attack against these infrastructures.
      </p>
    </sec>
    <sec id="sec-3">
      <title>3. REFERENCE STANDARDS</title>
    </sec>
    <sec id="sec-4">
      <title>3.1 Italian National Framework of Reference</title>
      <sec id="sec-4-1">
        <title>Based on the above definition, the Operation Technology Critical Infrastructure can be</title>
        <p>
          defined, in accordance with Legislative Decree 61 of April 11, 2011, as: "An infrastructure,
located in an EU Member State who are essential for the maintenance of vital societal
functions, health, safety and economic and social welfare of the population, and the disruption
or destruction of which would have a significant impact in that State because of inability to
maintain those functions."
This definition, based on the aforementioned legislation itself, has expanded through the
introduction of "European Critical Infrastructure (ECI)" defined as critical infrastructure
located in the EU Member States the disruption or destruction of which would have a
significant impact on at least two Member states. The importance of this impact is assessed in
terms of cross-sector in relation to the involvement of different types of infrastructure.
In this context, in Italy, the Ministry of Defence and other ministries such as Interior and
Economic Development, within their respective competences, put in place all the actions and
measures necessary to ensure the protection of ECI located in national territory without
prejudice to the responsibility at the local level the protection of the individual installations, the
ECI constituents are attributed to the territorially competent prefect (
          <xref ref-type="bibr" rid="ref6">5</xref>
          ).
        </p>
      </sec>
      <sec id="sec-4-2">
        <title>The Legislative Decree 61 also establishes the Inter-Ministerial Nucleus Situation Planning</title>
        <p>(NISP) and contains the definition of the Security Plan for operators of European Critical
Infrastructures. At NISP (at the Prime Minister's Office in collaboration with the relevant
ministries) entrusted with the identification and designation of ECI, the head structure
(Secretariat for Critical Infrastructure, "SIC") for the technical and scientific work necessary for
NISP functions and relations with the Commission and other Member States affected by the
ECI that Italy intends to designate.</p>
        <p>The Critical Infrastructure has been identified by the European Commission, after much debate,
with the promulgation of the European Commission Directive COM (2006) 787 which
identified 11 critical areas ranging from energy to communications, from transport to food.</p>
      </sec>
    </sec>
    <sec id="sec-5">
      <title>3.2 Outline of the international regulatory framework</title>
      <p>The Legislative Decree 61 of April 11, 2011, was accepted by the Italian implementing
Directive 2008/114 / EC on the identification and designation of European critical
infrastructures and aims to evaluate the need to improve their protection.</p>
      <p>Therefore, the definitions of CI and ECI are consistent among all the EU member states with
those illustrated in the preceding paragraph.</p>
      <p>In the UK Cabinet Office defines Critical National Infrastructure (CNI) those "infrastructure,
physical and electronic that are vital to ensure the integrity and availability of essential services
and the disruption or impairment may result in economic or social damage or loss of lives. "
The CNI spanning nine areas ranging from energy to communications, from transport to
financial services.</p>
      <sec id="sec-5-1">
        <title>Britain has set up a “Center for the Protection of National infrastructure” (CPNI), which</title>
        <p>
          represents the structure of government that oversees the protection and security of the CI.
Across the Atlantic, the US has identified 16 types of critical infrastructure in those sectors
whose structures, systems and networks, physical or virtual are considered vital because if
destroyed or altered may cause effects on national security. In this regard has been issued a
directive, the Presidential Policy Directive 21 (
          <xref ref-type="bibr" rid="ref7">6</xref>
          ) where there are the guidelines aimed to
maintain safe, functional and resilient critical infrastructure.
Below is a comparative diagram of the IC identified within the EU, UK and USA.
        </p>
        <p>EU
ICT</p>
        <sec id="sec-5-1-1">
          <title>Water</title>
        </sec>
        <sec id="sec-5-1-2">
          <title>Energy</title>
        </sec>
        <sec id="sec-5-1-3">
          <title>Nuclear</title>
        </sec>
        <sec id="sec-5-1-4">
          <title>Food</title>
        </sec>
        <sec id="sec-5-1-5">
          <title>Health</title>
        </sec>
        <sec id="sec-5-1-6">
          <title>Financial</title>
        </sec>
        <sec id="sec-5-1-7">
          <title>Transport</title>
        </sec>
        <sec id="sec-5-1-8">
          <title>Chemical industry</title>
        </sec>
        <sec id="sec-5-1-9">
          <title>Space</title>
          <p>GB</p>
        </sec>
        <sec id="sec-5-1-10">
          <title>Communications</title>
        </sec>
        <sec id="sec-5-1-11">
          <title>Water</title>
        </sec>
        <sec id="sec-5-1-12">
          <title>Energy</title>
        </sec>
        <sec id="sec-5-1-13">
          <title>Food</title>
        </sec>
        <sec id="sec-5-1-14">
          <title>Health care</title>
        </sec>
        <sec id="sec-5-1-15">
          <title>Financial services</title>
        </sec>
        <sec id="sec-5-1-16">
          <title>Transportation</title>
        </sec>
        <sec id="sec-5-1-17">
          <title>Government</title>
        </sec>
        <sec id="sec-5-1-18">
          <title>Emergency services</title>
          <p>USA
Information Technology
Communications +</p>
        </sec>
        <sec id="sec-5-1-19">
          <title>Water + DAMS</title>
        </sec>
        <sec id="sec-5-1-20">
          <title>Energy</title>
        </sec>
        <sec id="sec-5-1-21">
          <title>Nuclear</title>
        </sec>
        <sec id="sec-5-1-22">
          <title>Agriculture and food</title>
        </sec>
        <sec id="sec-5-1-23">
          <title>Public health care</title>
        </sec>
        <sec id="sec-5-1-24">
          <title>Banking and Finance</title>
        </sec>
        <sec id="sec-5-1-25">
          <title>Transportation system + Postal and shipping</title>
        </sec>
        <sec id="sec-5-1-26">
          <title>Chemical</title>
        </sec>
        <sec id="sec-5-1-27">
          <title>Monuments and icons</title>
        </sec>
        <sec id="sec-5-1-28">
          <title>Government facilities</title>
        </sec>
        <sec id="sec-5-1-29">
          <title>Defence industrial base</title>
        </sec>
        <sec id="sec-5-1-30">
          <title>Commercial facilities</title>
        </sec>
        <sec id="sec-5-1-31">
          <title>Emergency services</title>
          <p>critical manufacturing</p>
        </sec>
      </sec>
    </sec>
    <sec id="sec-6">
      <title>4. THE ICS AND SCADA SYSTEMS</title>
    </sec>
    <sec id="sec-7">
      <title>4.1 Definition</title>
      <sec id="sec-7-1">
        <title>The production processes are managed through Critical Infrastructure Industrial Control</title>
        <p>System (ICS) which generally consist of different types of systems for electronic monitoring of
the physical plant, including that of supervision and data acquisition (SCADA- Supervisory</p>
      </sec>
      <sec id="sec-7-2">
        <title>Control and Data Acquisition).</title>
        <p>Distributed Control Systems (DCSs) are typically used within a single process or generating
plant, or used over a smaller geographic area or even a single-site location.</p>
      </sec>
      <sec id="sec-7-3">
        <title>Supervisory Control and Data Acquisition (SCADA) systems are typically used for large-scale</title>
        <p>
          environments that may be geographically dispersed in an enterprise wide distribution operation.
(
          <xref ref-type="bibr" rid="ref8">7</xref>
          )
An ICS \ SCADA is, therefore a system that monitors in real time one or more industrial plants
in order to reduce the costs of monitoring of machinery and increase automation and
productivity.
        </p>
        <p>The peculiarity of a SCADA other than ICS is that it monitors and controls systems over large
geographical areas through communication infrastructure such as radio, satellite, telephone
networks; It is composed of sensors associated with "remote terminal units" (RTU) that collect
data and verify the condition of machinery and industrial processes, and that subsequently, after
processing, send them to the plant or “master terminal unit” (MTU) control station.
The ICS \ SCADA systems allow to monitor in real time situations and so that the data obtained
are used by third-party systems.</p>
        <p>In the area of defence oversee ICS systems, for example, the energy management of a base, or a
naval vessel but also the management of weapons systems of a tactical vehicle. Even the latter
can be understood as an ICS as it controls a process and monitors the operation.
This overview aims to depict how the ICS systems are not peculiar to certain industrial
processes, but rather permeate our daily lives, managing many aspects.</p>
      </sec>
    </sec>
    <sec id="sec-8">
      <title>4.2 From 2010 to nowadays: a rapidly changing cyber security environment</title>
      <p>The nature of the ICS, mainly oriented to the operation and the provision of seamless services
24h / 365, often makes it difficult to ensure the safety of the infrastructure in accordance with
the same philosophy of Information Technology apparatuses.</p>
      <p>In recent years, ICS, for economic reasons linked to the development and maintenance, they are
directed to the use of hardware and software business and the use of common communication
protocols, yet the ICS world still looks still varied and bound not to standardized protocols but
implemented and customized protocols by market leaders.</p>
      <p>As for IT systems, it is essential a support management that guarantees "as soon as possible" to
install updates of application, minimizing user impact, and an improvement of the system
security, for ICS instead the regular patch installation and implementation of software security
measures, if not properly checked, could result in impacts on functionality.</p>
      <p>Consider also that in some cases the management systems employed in these types of systems
are at the end of life and therefore no longer supported by the parent with patching security.
In this regard, by way of example, consider that most of the SCADA software is based on
operating system "Windows Millennium Edition" whose safety support has ended in 2006.
Also, and this is an aspect far from negligible, to be competitive in the market companies need
to produce systems with lower costs and eventually functionality similar to or better than their
competitors.</p>
      <p>This simple statement, linked to the realization that develops and design safely is a significant
cost, means that many of the currently available systems not only represent a risk to the cyber
environment but also for the physical, given the implications that they may have.</p>
    </sec>
    <sec id="sec-9">
      <title>4.3 A recent example of attack: Black Energy 3</title>
      <p>
        On December 23, 2015, in Ukraine, (
        <xref ref-type="bibr" rid="ref9">8</xref>
        ) an electricity distribution company, Kyivoblenergo,
interrupted the service to about 225,000 clients, declaring that the blockage was caused by the
illegal entry of third parties in the company's control system and the ICS \ SCADA systems.
Later it was stated that the cyber-attack had been so pervasive as to affect most sections of the
network and push the central administrators to switch to the manual operation mode.
The cyber defences, despite being highly structured, have been bypassed by using a wide range
of vectors including aggressive spear phishing emails, malware variants BlackEnergy 3 and
handling of Microsoft Office files.
      </p>
      <p>It is evident that such an action, the high level and the amount of force put in place, was
conducted by an entity able to:
§ conduct intelligence activities to get to know the target system;
§ shape the central bank, at least through the use of similar technology as turbines, PLC,
power grid;
§ production malware 0-day.</p>
      <p>From a technical point of view the probable attack sequence can be described as follows:
§ a spear phishing email in which was contained malware "BlackEnergy 3" that exploited
0-day vulnerabilities;
§ the theft of passwords in enterprise networks;
§ using Virtual Private Networks (VPN) to access the ICS network;
§ remote access from intruder with full control of the SCADA control systems;
§ access to serial devices and Ethernet as well as communication through the firmware;
§ using a "KillDisk" software to erase in a targeted number of useful instructions and
backup to prevent the restart system automatically in the event of failure;
§ using the UPS system load systems for interruption of service;
§ denial-of-service attack against the call center to prevent communication.</p>
    </sec>
    <sec id="sec-10">
      <title>5. CURRENT ISSUES: NEED FOR A COMPREHENSIVE POLICY</title>
      <p>One of the biggest obstacles is the lack of accurate data and information relating to cyber
incidents that flock to the SCADA. Often companies concerned, mainly for not undermine the
trust placed in them by investors and customer, don’t state when and if they were interested in
the attacks.</p>
      <p>
        Also consider that in a world so interconnected, and the case of Stuxnet (
        <xref ref-type="bibr" rid="ref10">9</xref>
        ) teaches, no one can
be considered immune to this type of threat, even air-gapped networks systems can be the
object of attack.
      </p>
      <p>With this background, it is necessary to provide a method to ensure the continuity of services
provided by ICS and policies to define how their cyber security needs to be addressed and
guaranteed.</p>
      <p>This continuity can be ensured by developing, on one hand, the static and dynamic security
policies, in fact the recent trend speaks of defence activities and proactive activities, on the
lines of those already implemented and constantly developing in IT and, on 'other, providing
integrated policies to ensure a longer life to the OT system (through for example the retrofit)
and a resilience to attacks.</p>
      <p>This policy, which we like to call "comprehensive", can be decomposed into several
macroactivities:
§ risk assessment;
§ static protection;
§ proactive defence;
§ resilience;
§ retrofit;
§ transportation vectors;
§ security by design;
§ safety culture and cyber teams.</p>
    </sec>
    <sec id="sec-11">
      <title>5.1 Risk assessment</title>
      <p>The first consideration to be made in order to have an effective security policy for
enterprise IT and OT, and in particular for the ICS system, is on the implementation of risk
analysis designed to identify which are the most sensitive parts exposed to a possible attack.
The risk analysis allows a census of the system components as a function of the threat, the
level of vulnerability and the probability that it will be attacked. This allows to produce a
list with the priorities of the system components to be protected by the appropriate security
policy.</p>
      <sec id="sec-11-1">
        <title>The Morgan‘s formula allows to summarize what was said: R = t * v * fourteenth Where R = risk, threat = t, v = vulnerability and fourteenth = probability that the vulnerability being exploited (10).</title>
        <p>From 2004 to date it was produced numerous documents and papers with the objective of
defining security standards for ICS.</p>
        <p>
          There are different methods that could be applied to ICS systems (
          <xref ref-type="bibr" rid="ref11">10</xref>
          ), but few of these
have specifically been studied for such systems, and even fewer of these are supported by
tests in real environments. This situation is a constant in the ICS, where very often
considerations and aspects of the IT world are borrow forgetting that the main
specifications of the OT systems require more detailed analysis, because as we noted above,
despite the technology can be very similarly, the objectives are different, and therefore the
relative risk should be supported by different evaluations.
        </p>
        <p>Therefore, the need to develop, after the analysis of the uniqueness of the environment OT,
a risk assessment methodology both quantitative and qualitative, which can be applied to
those specific cases.</p>
        <p>
          To this end, we propose the use of two different frameworks as a starting point, as it may
represent the proper mix of qualitative analysis and quantitative necessary.
We will discuss primarily the framework "OCTAVE Allegro" (
          <xref ref-type="bibr" rid="ref12">11</xref>
          ) and then we will pass to
an analysis of the "Italian National Framework" (
          <xref ref-type="bibr" rid="ref13">12</xref>
          ).
a. OCTAVE Allegro
        </p>
        <p>This method consists of 8 steps, arranged in turn in 4 stages, as shown below.
In the first phase, the organization is asked to identify the drivers of the audit and general
criteria, such as the activity guidelines. In the second stage, we are witnessing the definition
of the analysis scope, through the formalization of the assets exposed to risk, with their
specific detail, and which are subject to audit.</p>
        <p>In the third and fourth phase the focus is moved to the concept of risk: identifies the dangers
that may insist on asset previously surveyed, are analysed, evaluated and finally developed
the response of the same solutions and risk mitigation.</p>
        <p>Every step, in turn, is divided into a series of activities (in fact the standard controls), which
guide the Auditor in the activity.</p>
        <p>Unlike other approaches to risk analysis - as the case of NIST and the “Italian National
Framework” treated more forward whole family OCTAVE outlines a roadmap through the
various steps, activities, and related controls, the auditor has to follow, through maximum
ease of use.
b. National Framework for cyber security</p>
        <p>
          In Italy has been presented the "National Cyber Security Framework” (
          <xref ref-type="bibr" rid="ref13">12</xref>
          ) that comes "with
the aim to offer organizations a voluntary, uniform approach to dealing with cyber security
in order to reduce the risk linked to the cyber threat".
        </p>
        <p>The National Framework was founded on the basis of the "Framework for Improving</p>
        <sec id="sec-11-1-1">
          <title>Critical Infrastructure Cybersecurity" developed by the National Institute of Standards and</title>
          <p>Technology (NIST), in the US, from which it inherits much of the central components, but
adapting to the Italian production, it made up mostly of Small and Medium Industry
(SMEs).</p>
          <p>Choosing the NIST as the reference standard was made on the one hand to ensure full
integration with the international contexts and, for another, despite being born in the field of
critical infrastructure, it can effectively adapt even in contexts less complex and highly
developed.</p>
          <p>Indeed, the structure is divided into a main component (Core) and introduces two
fundamental notions, Profile and Implementation Tier.</p>
          <p>Compared to the structure of NIST, the National Framework varies with the introduction of
the concepts of priority levels and maturity levels needed to make their own controls and
indications more closely reflecting the national economic environment.</p>
          <p>The effectiveness of the National Framework is given from being able to keep that enough
abstraction that allows adapting the audit in reality very different size, joints, business and
risk profiles, but at the same time specifically, have integrated indicators created in support
of SMEs.
c. ICS Risk Assessment</p>
          <p>One of the objectives with regard to the risk assessment is to define a basic framework, agile
and functional, can be used effectively and efficiently towards the ICS \ SCADA systems.
Such a framework will have as its starting point the methodology OCTAVE Allegro,
previously defined, and making a detailed evaluation of the controls implemented in the
national framework for cybersecurity, in particular, mapping these controls to reality and to
the OT goals. This evaluation will be described in detail as a result of the case study planned
as future works, in which will be evaluated the benefits and costs of the exposed approaches.
In this regard, it also highlights the need for sharing among agencies of the results of the
various risk assessment. Such sharing, carried out anonymously and based on the same type
and risk assessment methods would have an overall picture of the country's system risk and
would focus investment and security initiatives.</p>
          <p>Therefore, the proposal of a shared framework for OT systems may have a significance not
only for the company but also for the country system.</p>
        </sec>
      </sec>
    </sec>
    <sec id="sec-12">
      <title>5.2 Static Protection</title>
      <p>At the approach light-encompassing, as a result of the risk assessment, which is the guideline
for the implementation and evaluation of the state of the ICS system, it is essential to ensure the
security of the implementation of "static" security measures, which contributes to reducing the
areas of physical and logical attacks.</p>
      <p>In particular, in relation to the threats that can target an ICS system, it is necessary to establish
certain physical security criteria, personnel, software and hardware used, detailed described in
this paragraph.
a. Physics Safety Requirements and physical access
b. Safety Requirements of personnel</p>
      <p>It includes all the necessary countermeasures to make a secure environment and to prevent
the physical damage of the equipment caused by unintentional, intentional or accidental
actions.</p>
      <p>These measures relate to the infrastructure, the access control and technological systems
used.</p>
      <p>Below is presented a comprehensive of the measures that are important to ensure the
physical security of the entire structure from the overall system functionality up to the
individual PLC:
§ hardening of the infrastructure that host terminal and the sensors through the gratings
installation, armoured doors, video surveillance mechanisms;
§ access management and control lists (for example, with an access list of authorized
personnel in a specific area/sensor);
§ supervision, registration and accompaniment of unauthorized personnel;
§ physical access control (locks on the doors, keys, magnetic cards, guards, access lists);
§ physical security of servers, terminals, peripherals, MTU, RTU, PLC;
§ physical protection of facilities and utilities (air conditioning, power supply) for critical
and essential systems;
§ procedures for media labelling, their protection and destruction;
§ physical security of communications in the WAN (if feasible);
§ control of electromagnetic compromising emanations with the definition of "bubbles"
(if feasible);
§ the discussion of procedures for the hardcopy output of the system depending on the
sensitivity of the same level;
§ for the scattered sensors / PLC along with the network, wherever possible, to provide
physical burglar tools type that prevent access or that the marker occurred burglary.
The staff employed in areas and on the part of the more sensitive system must be if
permitted and to the extent possible, subjected to reliability verification, through a sort of
"Security Clearance" for operators.</p>
      <p>It also needs to implement the policies on a model of "dual key" system that would prohibit
unaccompanied staff to be able to compromise the functionality of the system.
c. Security of the "source"</p>
      <p>One of the main point of failure, because skipped in most cases, is the need to "validate the
source" the hardware components and software used. In other words, a fingerprint must be
able to ensure that part of the code and/or hardware component that I am going to
implement, must have been previously tested and validated according to the reference
standards.</p>
      <p>In this regard, it is also important to note the tendency to use as well as validated and
certified technology, the domestic technology for critical systems, this trend is amplified if
we consider also modern “Internet of Things” devices.
d. Limitations of physical and logical access to the ICS network</p>
      <p>In order to reduce the risk of impairment of networks that are usually air-gapped, it is
necessary to implement access restrictions that must provide at least the following measures
for both physical and logical:
• use of unidirectional gateway;
• demilitarized zone (DMZ);
• a separate corporate network from the ICS and creating separate VLANs logically;
• the use of VPN and "jump server";
• safety of transport carriers such as encrypting communication in the WAN (if
feasible) to ensure the safety of transport carriers, satellite, radio networks through
the use of cryptographic devices and deployment of VPN;
• allow access to the corporate network and ICS defined only by authorized devices
and certificates;
• creation of dedicated management stations;
• network access control;
• separate mechanisms and authentication credentials for users of corporate networks
and ICS networks.</p>
      <p>The ICS systems should also use a network topology that has multiple layers, depending on
the sensitivity of the information level, the most critical communications that occur in the
most secure and reliable layer.</p>
      <p>In order to make clearer, the discussion is presented in the following figures, merely by way
of example and not however completely explanatory, two of the possible network
architectures.</p>
      <p>VPN</p>
      <p>FW</p>
      <p>DMZ
Jump</p>
      <p>FW
«HTTP» Server</p>
      <p>MTU</p>
      <p>RTU
PLC</p>
      <p>RTU
PLC
VPN</p>
      <p>FW</p>
      <p>DMZ
Jump</p>
      <p>Collegamento non</p>
      <p>Ethernet</p>
      <p>MTU
FW
Figure 2 is a network diagram with a VPN which allows connection to external devices,
double firewall protection, a DMZ, the presence of a "Jump Server" and a web server for the
management of the internal actuators to the ICS management network not "Ethernet"
connected.</p>
      <p>Management Station: These positions will have to be configured to discriminate access to
administrators and will be inserted in the site VPN management. Only such a station will be
enabled to make changes to the configuration of the network management apparatus and the
information logical structure.</p>
      <p>Network Access Control: In the context of a considerable increase in the overall security
level, you must take the "Network Access Control" policy to prevent malicious access by
unauthorized devices. Such control makes it possible to associate a particular authentication
policy to the devices within the network, by limiting access to unauthorized devices. This
criterion may be the MAC address of the association of the device in the simplest systems or
the association of the authentication device behaviour, evaluated continuously done by
performing a continuous authentication. The absence of such control could allow an attacker
to connect in a relatively simple manner to the network equipment if there is the physical
availability of access to the area.
e. ICS Software Protection</p>
      <p>In critical environments such as the ICS there is a need to provide for a series of measures
for the protection of software, such as:
§ implementation of policies for managing devices and locations of "scrub";
§ the anticipation of a test environment for the functionality of these security patches and
anti-virus;
§ predict the distribution of security patches, after having suitably tested in field
conditions;
§ predict the dynamic implementation of measures that will underpin the perimeter
security;
§ implementing centralized antivirus and IPS / IDS to detect the malware and malicious
traffic and mitigate risks;</p>
      <p>Near real-time monitoring activity
§
§
§
§
§
§
§
§
§
§
implementation of systems that allow certain operations (e.g. change of configuration)
through the generation of an "OTP – One-time password" or implementation of
biometric control systems;
implementation of security policies, if possible but that provide centralized access to the
stations in question according to the principle of "least privilege";
implementation of BIOS password, the definition of a baseline software configuration
as well as boot configuration so as to allow the starting of the operating system only
from the hard disk;
expiration of the "work session" from the outside after a defined period of time;
disabling all unused ports and services and ensuring that they remain deactivated;
monitoring and log management relating to the activities of interest defined on the basis
of the risk assessment;
implementation of virtual environments in order to put in place policies backup and
restore;
policies for the inclusion of new users and managing the account lifecycle;
the control of the hardware configuration and software of the system;
implementation of the complexity of the access password policies.</p>
      <p>One of the main activities to be performed for the safety of OT in a distributed environment,
is the ability to monitor sensors constituents of the system itself. For the implementation of
such a system reference is made to a more general architecture of analytics data, known as
"Kappa Architecture". It is illustrated in the following figure:
The architecture Kappa, Lambda Architecture evolution, is characterized by the
characteristic of being able to carry out, through same application code (within the
Realtime Layer represented in the figure) either batch processing that type of Real-time type,
reducing so much time and cost of development of analytics capabilities.</p>
      <p>In this architecture, the object of analysis input data is taken typically by accessing an Event
Bus ("Incoming Data"), which guarantees an asynchronous behaviour between the various
manufacturers of such data and the functionality of Data Analytics which uses them; the bus
also has characteristics of fault-tolerance.</p>
      <p>The acquired data are persisted (and unchanging - append only) and constitute the archive
called "Historical data storage" in the figure above. The results of computations performed
by the Real-Time Engine are kept instead in a file called "Results Storage."
A detail of the architecture is shown in the following figure:</p>
      <p>14
The Kappa architecture lends itself to be carried out by using different technological
platforms, for the modules that constitute it. As part of this project, it was identified as the
optimal selection of the following platforms.</p>
      <p>a) Apache Kafka for the acquisition functionality and data buffering and acquired
events;
b) Flink Apache / Apache Storm, for real-time analysis of the simulation events or
deferred as provided in Architecture Kappa;
c) Elasticsearch, for the data storage (indexing events of interest collected during an
exercise and results of operations analytics);
d) Kibana and Grafana, for access to the results of the analysis (in real time or
delayed), the creation of dashboards, scheduling of reports.</p>
      <p>The target architecture of the analysis system is then represented in the following figure:
Such a monitoring system, efficient and effective for the management of numerous flows of
varied and heterogeneous data, as often happens in ICS environments, leads to the creation
of what in the military sphere is defined COP (Common Operational Picture) generated
representing a situation in real time defined homogeneous joints of the installations
monitored and fed by similar sensors.</p>
      <p>It is possible through the use of dashboards to represent the state of health of all the air
conditioning systems of the examined systems. Such evaluation may be more or less
extended according to the needs and according to relevance. A COP, by monitoring the
functionality of the components, services not available and resources in the process of
saturation, allow developing policies that will ensure the ICS operation and management.
g. Detection of events and security incidents</p>
      <p>Defined in the previous paragraph the necessary monitoring capabilities, this must be linked
to a detection and response capacity.</p>
      <p>
        As evidenced by different field studies, time-to-detection for very virtuous companies is
estimated at about 50 days (
        <xref ref-type="bibr" rid="ref1">1</xref>
        ). For this purpose it is necessary to emphasize the importance
of having a set of tools that not only allow the detection but will allow the management of
the incident in all its phases, from remote analysis tools used to analyse presumably infected
workstations, to subsequent mitigation, containment and eradication, to reduce the risk of
further impairment. For this purpose, tools with dedicated signatures for research in memory
of particular behaviours associated with malware can be especially useful associated with all
directions given above.
      </p>
      <p>The detection and response should enable studies of the events in order to avoid future
incidents.</p>
    </sec>
    <sec id="sec-13">
      <title>5.3 Proactive Protection</title>
      <p>In recent years the trend of attacks and subsequent breach led to the realization that security
cannot be limited to the static protection, but must have a holistic approach based on the
detection.</p>
      <p>This awareness led to the use in a more or less distributed platforms of Active Defence and
Threat Intelligence capabilities.</p>
      <p>Active defence is the use of a range of tools and techniques aimed to achieve the following
capabilities:
§ annoyance;
§ attribution;
§ attack.</p>
      <p>As “annoyance” is meant the ability to disturb the intruder during the phases of the attack
in order to achieve the dual purpose of slowing it down and generate a "noise" that can be
detected by monitoring systems.</p>
      <p>As “attribution”, can be considered the ability to define, above any reasonable doubt, the
attack source.</p>
      <p>As “attack”, however, it is the counter-attack capabilities and quick response to threats.
In the ICS / SCADA ecosystem, these techniques are not adopted uniformly to both a lack of
sensitivity to the Active Defence, primarily due to an "old" legacy from those who manage
them and for the age of some of the systems, that prevent the compatibility with such tools.
In this regard, should be made clear the precise assumptions aimed at defining the threat
model to use in this context. In particular, we can assume that:
§ the attacker knows the services offered, the network infrastructure and applications in a
comprehensive manner but not as well as the defender. This assumption is reasonable
because the attacker has been enough time in the network to know whether or not the
smallest details as the defender;
§ the defender must implement measures of active defence, such as the range of services
ports, the names of critical files and so on. In essence, he must be put in place all those
Active Defence actions aimed to slow the attacker down, to reduce his knowledge of the
infrastructure and forcing to carry out a new assessment of the system.</p>
      <p>With a threat as relevant, the goal to be achieved by those who defend in a "proactive" is to
slow down as much as possible forcing the attacker to increase the time required to gain a
detailed understanding of the network; this can be done through the use in a combined or
individual of skills and techniques.</p>
      <p>To achieve Annoyance and Attribution, for example, often are implemented honeypot or
honey-net aimed at addressing the attacker towards non-critical objectives in order to have
more chances to perform the detection.</p>
      <p>This must go through the use and development of a series of specific tools aimed at 'active
defence, better if easily deployable and usable.</p>
      <p>A fairly recent trend leads to the development of a honeypot "adaptive" system comprising
the combined use of monitoring techniques, proactive defence and threat intelligence. Such
security infrastructure designed to detect behaviour outside the "norm", where normally
means all the behaviours common to all users.</p>
      <sec id="sec-13-1">
        <title>Penetration Testing</title>
        <p>Another key option to achieve proactive defence is perform periodically penetration testing
activities, from both internal team and external teams, to analyse the attack surface and
evaluate the real risk exposure of the infrastructure.</p>
        <p>The penetration testing is the set of activities aimed at identifying through the use of expert
operators, such as an ICS to respond to an intelligent and dynamic cyber-attack how and
whether it can be violated and what information can be gained from it. The penetration
testing includes, in principle, a number of activities that are listed below:
Information Gathering: phase of information regarding the target collection. Of
fundamental importance are the identification of sources, their number and subsequent
correlation and exploitation of the resulting data. The Gathering information can also be
classified into "passive" and "active" depending on the direct involvement of the
infrastructure of the target placed in the analysis.</p>
        <p>Vulnerability: refers to individuals, groups of individuals, software and SCADA protocols.
They are such exposures to threats that endanger the survival of the systems, integrity and
confidentiality of the data they contain and the services provided.</p>
        <p>Exploit: the tools (scripts, viruses or worms or binary), exploiting a specific vulnerability in
a computer system, allow the execution of malicious code aimed at obtaining administrative
privileges or not. They can be implanted in an ICS through the use of any vector
appropriately identified.</p>
        <p>An exploit in turn can be divided into different components such as payload, shellcode,
encoder
System &amp; Privilege Escalation: it means the exploitation of project errors, application
configuration, or holes in order to acquire the control of system resources normally
precluded to a user or application.</p>
        <p>Post-Exploitation: once within the system, the attacker sets up activities aimed at
maintaining the access to exploitation system level (persistence). It may be actually
included all activities for collecting data (packet sniffing, pivoting, patching level, network
settings, etc.) in preparation for future activities related to further exploiting, pivoting and
privilege escalation. It is the highest stage of system compromise.</p>
      </sec>
      <sec id="sec-13-2">
        <title>Vulnerability Assessment</title>
        <p>The process aimed at assessing the effectiveness of the systems and the security level
acquired. The aim of this research is to identify the loopholes in the system analysed so that
it can improve and prevent attacks based on specific vulnerabilities. Given the number of</p>
      </sec>
    </sec>
    <sec id="sec-14">
      <title>5.4 Resilience</title>
      <p>new vulnerabilities discovered every day is crucial perform the VA with the right frequency
in order to ensure that the system configurations are correct and appropriate security
patches applied.</p>
      <p>Resilience involves the ICS design so that every critical component is redundant and that, in
the case of failure, will be excluded from the network and does not generate unnecessary
traffic on the network causing the cascading events. This expresses the need to find, in the
case of attack, the methods that allow not to turn off "tout court" but the system that allow
me to predict the extent to which an ICS if attacked is able to resist (the concept of resilience
classes).</p>
      <p>The resilience must allow a degradation "attenuated" passing by "normal operation" of the
ICS to "emergency operations" through automated procedures or able manuals, this will be
addressed in the future works in which a specific case study will be analysed.
When ICSs are part of the so-called critical infrastructure (CI), then Their correct behaviour
Becomes essential for the maintenance of vital societal functions. This is Because the
damage to a critical infrastructure, its destruction or disruption by terrorism, criminal
activity or malicious behaviour, may have a significant negative impact on the security of
the EU and the well-being of its citizens.</p>
      <p>Reducing the vulnerabilities of critical infrastructure and increasing time Their resilience is
one of the major objectives of the EU. In Particular, analysing the resilience of a system is
of paramount Importance from a system maintainer's standpoint. This is Because, in spite of
all the prevention and detection policies That might be applied to protect a specific ICS, the
risk of an undetected intruder That penetrates the system and tampers with its parameters
cannot be eliminated completely. Systems with a high built-in resilience are less prone to
service disruption Because it is harder for the intruder to bring the system outside the
boundaries of correct action, and this leaves to the maintainers more time to identify, isolate
and defy the menace without causing major service disruption. It is expected That resilience
analysis Should Provide the maintainers with a concise quantitative measure of resilience
Obtained, e.g., by comparing the system boundaries stability under normal working
conditions with the same boundaries considering various attack scenarios. Under this
perspective, a highly-resilient system is one in which the overall stability is maintained even
in the face of large modifications Affecting one or will more regulation parameters. In order
to evaluate resilience, outline as before, one could consider various approaches including
state-of-the-art control theory, simulation and AI techniques. In Particular, it is possible to
devise systems whereby the ICS under test is attacked by intruders simulating intelligent
programs, or, alternatively.</p>
    </sec>
    <sec id="sec-15">
      <title>5.5 Retrofit</title>
      <p>One of the major issues related to the implementation and development of ICS systems is
the difference between the life cycle of ICS systems and the life cycle of their hardware and
software. This is particularly reflected in those installations where the cost of construction
and installation take several decades to be depreciated, while the component becomes
obsolete and obsolescence is also accompanied by the risk related to the impairment of the
equipment.</p>
      <p>To address this risk is important to know that the maximum evaluations linked to
technological life of some ICS systems, linking them to data with those derived from the
quantitative risk assessment of obsolescence for IT systems.</p>
      <p>
        For this purpose, we take as a reference, purely by example, the life cycles of Microsoft
systems; this assessment is dictated primarily by the availability of documentation (
        <xref ref-type="bibr" rid="ref14">13</xref>
        ) and
the presence of important agreements of partnership between leading companies ICS and
Microsoft field.
A considerable discrepancy is detected between Figures 8 and 9, in fact, while the average
life of an IT system is about 7-8 years before becoming obsolete, for OT systems this value
is at least 10 years.
      </p>
      <p>In the light of this assessment, it has in the best possible condition a lack of quantifiable in
about 2 years. In the best-case scenario, considering the number of vulnerabilities found and
resolved during the year it has very high exposure to critical systems without the possibility
of having a resolution of the problem.</p>
      <p>From this qualitative risk assessment, it is considered that even the best-case scenario is
minimally acceptable for an ICS.</p>
      <p>To this regard it is important the introduction of the concept of "Evolution without
obsolescence", i.e. a process in which both the purely OT part both the portion IT to support
must converge to a correct management of the lifecycle of systems. This development,
safeguarding security, can be continuously carried out without too many and heavy charges.
To achieve this goal, which turns out to be the primary for the effective mitigation of the
risk during the life cycle, it is necessary to adopt lines of development according to the
principles of the “secure development lifecycle”, in order to have systems which in their
phases will follow a process replicable and quantifiable, and whose management, upgrades,
disposal does not require a continuous design "ex novo" but vice versa are considered parts
of a constant development process.</p>
      <p>This phase must be preceded by a risk assessment that highlights the most critical obsolete
components for the industrial plant operation: interruptions in service and upgrades of
legacy systems should be planned with a reasonable period in advance.</p>
    </sec>
    <sec id="sec-16">
      <title>5.6 Security by Design</title>
      <p>As indicated in Section 5.5, one of the major risks arising from ICS systems is related to the
different life cycle of the various components that constitute them. In this context, it is
necessary that both a supportable and resilient system then comprising a security process by
design for the development and testing of the ICS.</p>
      <p>Therefore this suggest a guideline to follow for the development of ICS systems, named</p>
      <sec id="sec-16-1">
        <title>Security Development Lifecycle (SDLC).</title>
        <p>The SDLC process has been thoroughly discussed in the literature, in particular by leading
companies in the software development industry. Rarely it was used for the development of
complete hardware and software but it is certainly one of the methods that allow part of the
security implementation right from the design part.</p>
        <p>The SDLC can be divided into 7 different phases, which are described below:
§ Training
§ requirements
§ Design
§ Implementation
§ Verification
§ Release
§ Response
Accompanied by the part of SDLC there is the necessary capacity to understand and shape
the threat as more realistic and exhaustive as possible, especially with the application of
what is considered "Threat Modelling". In this regard, can be indicates as one of the most
reliable for making threat modelling and related mitigation the STRIDE model:
§ spoofing
§ tampering
§ repudiation
§ information disclosure
§ denial of service
§ elevation of privilege
To which we associate the following mitigations:
§ authentication
§ integrity
§ non-repudiation
§ confidentiality
§ availability
§ authorization
This adds specific best practices:
§ all software developed must not consist of software or parts of it open source;
§ they must be provided for laboratory environments able to verify the patching in order
to ensure that the integrity of the system is maintained.</p>
      </sec>
    </sec>
    <sec id="sec-17">
      <title>5.7 Safety culture and cyber team</title>
      <sec id="sec-17-1">
        <title>Safety culture</title>
        <p>Violations / IT impairments are often favoured in unintended ways by users. The tools and
next generation security policies become more sophisticated and efficient but their
effectiveness can be attenuated by users’ improper conduct. This demonstrates that
computer security is a shared responsibility throughout the organization. In this context, it
considers it necessary to resort periodic indoctrination programs for staff as well as the
drafting of specific regulations that contain the basic rules of good behaviour.
It is also necessary to provide cybersecurity team and those elements of the organization
created specifically to ensure the information security infrastructure. They must be
composed by different professionalism. In principle must consist of managers and system
administrators are responsible for the network configuration, security experts and a manager
to the physical security. Also, a member of the cyber component must be part of the
management board in order to represent the cyber security issues at the highest levels.</p>
      </sec>
      <sec id="sec-17-2">
        <title>Education and training</title>
        <p>It is necessary to realize an integrated platform for the training bench, in the field of
cybersecurity and to the testing of cyber technologies of ICS in a highly dynamic and evolving
environment.</p>
        <p>This platform, aimed at the education and training of specialist staff, must be:
§ dynamic with the ability to adapt and extend its modelling capabilities, virtualization and
simulation of real-life contexts in terms of environments and IT technologies and strategies and
cyber-security techniques;
§ flexible with the ability to adapt to environments and contexts of use different and
varied with different cultures, differing practices, specific operational methodologies;
In addition, if the orientation was open to operational cooperation with other national and
international entities and the sharing of tools, components and common good results, the
platform must be interoperable.</p>
        <p>This training platform will provide:
§ operator training through introductory and specialized courses;
§ training through the design of contexts and scenarios to emulate environments and
configurations cyber-attack as realistic as possible through to use ICS bench "modelled",</p>
      </sec>
      <sec id="sec-17-3">
        <title>Research, Testing and Development</title>
        <p>The primary requirements are added, through a constant evolution as:
§ experimentally validating the research of new cyber solutions for OT;
§ providing an environment where testing the software, hardware, actuators and sensors
by verifying and validating new solutions in the field of cyber security;
§ enabling the development of “techniques, tactics and procedures” (TTPs) targeted both
response to hostile activities and the conduct of offensive activities.</p>
      </sec>
    </sec>
    <sec id="sec-18">
      <title>6. CONCLUSIONS</title>
      <p>
        These days, the “time to detection” of a malicious activity on traditional IT systems (
        <xref ref-type="bibr" rid="ref1">1</xref>
        ) (
        <xref ref-type="bibr" rid="ref15">14</xref>
        ) is
stood over an average of more than 50 days, even considering the most virtuous environments.
The threat level in recent years and the evolution of asymmetric warfare oriented towards the
use of cyber-attack against ICS systems also reminds us that the trend for the future involves
more sophisticated and advanced attacks, involving not only the cyber but also the physical
world.
      </p>
      <p>While it is undeniable that ICS systems are normally designed to withstand the technical failure
through redundancy it is also true that redundancy, and the case of black energy proves it, may
not be enough to deal with structured malicious attacks.</p>
      <p>
        It is therefore necessary to implement measures so as to enable the integrity of the system both
during normal operations and during the cyber-attack. Such measures must not only be of a
technical nature but must take into account, the bulk point of vulnerability is represented by
man. For instance, the case Stuxnet (
        <xref ref-type="bibr" rid="ref10">9</xref>
        ) teaches that the malware has been introduced into the
plant control network by a little zeal technician.
      </p>
      <p>
        Also attacks on ICS systems have so far been conducted by organizations technologically and
logistically advanced which means that only those who are structured and has significant
resources can think of a successfully attack an industrial plant (
        <xref ref-type="bibr" rid="ref16">15</xref>
        ) (
        <xref ref-type="bibr" rid="ref17">16</xref>
        ).
      </p>
      <p>Hence the need to provide a 360-degree policy, which is not to omit any aspect and consider all
aspects of the man-machine combination.</p>
      <p>The current trend shows that all the major industrial powers, primarily in the United States, are
working on ICS environment to make them as security compliance as possible. Only the
escalation into more damaging hostile acts against ICS enabled the cyber security in this
particular area, and recently, to become a priority.</p>
      <p>The conclusion of this paper is to raise awareness of the need to develop and consolidate a
culture of cyber security for ICS / SCADA starting a path that takes into account all aspects that
contribute to ensuring genuine cyber protection to OT.</p>
      <p>Therefore, the comprehensive approach can be summarised as follow: borrow and adopt best
practices and concepts already employed or developing in the industrial, military and academia
making them viable for reality ICS / SCADA.</p>
      <p>As future work, and a natural follow-up activities based on this paper, the practical
implementation will be consider, applying the indicated requirements in a real world scenario,
than will be considered as initial use case of ICS security in a military environment.
7. BIBLIOGRAPHY</p>
    </sec>
    <sec id="sec-19">
      <title>LIST OF FIGURES</title>
    </sec>
  </body>
  <back>
    <ref-list>
      <ref id="ref1">
        <mixed-citation>
          1.
          <string-name>
            <surname>FireEye. M-Trends</surname>
            <given-names>Reports</given-names>
          </string-name>
          <year>2017</year>
          . s.l. :
          <source>FireEye</source>
          ,
          <year>2017</year>
          . https://www.fireeye.com/currentthreats/annual-threat
          <source>-report/mtrends.html.</source>
        </mixed-citation>
      </ref>
      <ref id="ref2">
        <mixed-citation>
          2.
          <string-name>
            <surname>Gen</surname>
            <given-names>Graziano</given-names>
          </string-name>
          , CaSMD - Intervento Commissione Difesa Camera. www.camera.it. [Online]
          <year>2017</year>
          gennaio 25.
        </mixed-citation>
      </ref>
      <ref id="ref3">
        <mixed-citation>
          http://documenti.camera.it/leg17/resoconti/commissioni/stenografici/pdf/04/indag/c04_cibernetico/
          <year>2017</year>
          /01/25/leg.17.stencomm.
          <source>data20170125.U1.com04.indag.c04_cibernetico.0009.pdf.</source>
        </mixed-citation>
      </ref>
      <ref id="ref4">
        <mixed-citation>
          3.
          <string-name>
            <surname>CYBER</surname>
            <given-names>WAR</given-names>
          </string-name>
          ,
          <source>CYBER SECURITY. Gen Vestito, CIOC</source>
          .
          <year>2017</year>
          ,
          <string-name>
            <given-names>Rivista</given-names>
            <surname>Aeronautica</surname>
          </string-name>
          .
        </mixed-citation>
      </ref>
      <ref id="ref5">
        <mixed-citation>
          4.
          <string-name>
            <surname>Dereck</surname>
          </string-name>
          , Harp. Bridging the Divide. s.l. : Next Defence.
        </mixed-citation>
      </ref>
      <ref id="ref6">
        <mixed-citation>
          5.
          <string-name>
            <given-names>Parlamento</given-names>
            <surname>Italiano</surname>
          </string-name>
          .
          <source>Decreto Legislativo 61</source>
          . Roma : s.n.,
          <source>11 Aprile</source>
          <year>2011</year>
          .
        </mixed-citation>
      </ref>
      <ref id="ref7">
        <mixed-citation>
          6. 21,
          <string-name>
            <surname>Presidential</surname>
            <given-names>Policy</given-names>
          </string-name>
          <string-name>
            <surname>Directive</surname>
          </string-name>
          .
          <source>Critical Infrastructure Security and Resilience</source>
          .
          <year>2013</year>
          .
        </mixed-citation>
      </ref>
      <ref id="ref8">
        <mixed-citation>
          7.
          <string-name>
            <surname>Robert</surname>
          </string-name>
          , Radvanosky. Handbook of SCADA/Control Systems. s.l. : CRC Press,
          <year>2016</year>
          .
        </mixed-citation>
      </ref>
      <ref id="ref9">
        <mixed-citation>
          8.
          <string-name>
            <surname>Zetter</surname>
          </string-name>
          ,
          <article-title>Kim. Inside the cunning, unprecedented hack ukraine's power grid</article-title>
          .
          <source>Wired. [Online] 03 Marzo</source>
          <year>2016</year>
          .
          <source>[Cited: 10 Luglio</source>
          <year>2017</year>
          .] https://www.wired.com/
          <year>2016</year>
          /03/inside
          <article-title>-cunningunprecedented-hack-ukraines-power-grid/.</article-title>
        </mixed-citation>
      </ref>
      <ref id="ref10">
        <mixed-citation>
          9.
          <article-title>Cyber threats to critical information infrastructure</article-title>
          . Wilson, C. s.l. : Springer,
          <year>2014</year>
          , Cyberterrorism: Understanding, Assessment, and Response.
        </mixed-citation>
      </ref>
      <ref id="ref11">
        <mixed-citation>
          10.
          <article-title>A review of cyber security risk assessment methods for SCADA systems</article-title>
          . Cherdantseva, Yulia Burnap, Pete Blyth, Andrew Eden,
          <string-name>
            <given-names>Peter</given-names>
            <surname>Jones</surname>
          </string-name>
          , Kevin Soulsby, Hugh Stoddart, Kristan. s.l. :
          <string-name>
            <surname>Elsavier</surname>
          </string-name>
          ,
          <year>2016</year>
          , Computers &amp; Security, pp.
          <fpage>1</fpage>
          -
          <lpage>27</lpage>
          .
        </mixed-citation>
      </ref>
      <ref id="ref12">
        <mixed-citation>
          11. Carnegie Mellon University. Octave Allegro.
          <source>US-CERT. [Online] [Cited: 10 Luglio</source>
          <year>2017</year>
          .] https://www.cert.org/resilience/products-services/octave/.
        </mixed-citation>
      </ref>
      <ref id="ref13">
        <mixed-citation>
          12.
          <string-name>
            <given-names>CIS</given-names>
            <surname>Sapienza</surname>
          </string-name>
          .
          <source>Framework Nazionale. Framework Nazionale CyberSecurity. [Online] [Cited: 10 Luglio</source>
          <year>2017</year>
          .] http://www.cybersecurityframework.it/.
        </mixed-citation>
      </ref>
      <ref id="ref14">
        <mixed-citation>
          13.
          <string-name>
            <surname>Microsoft</surname>
          </string-name>
          . Lifecycle.
          <source>Microsoft Support. [Online] [Cited: 10 Luglio</source>
          <year>2017</year>
          .] https://support.microsoft.com/it-it/lifecycle.
        </mixed-citation>
      </ref>
      <ref id="ref15">
        <mixed-citation>
          14. NIST. NIST Special Publication 800-82 Revision 2
          <article-title>- A guide to Industrial Control System (ICS) Security</article-title>
          . s.l. :
          <source>NIST</source>
          ,
          <year>2015</year>
          .
        </mixed-citation>
      </ref>
      <ref id="ref16">
        <mixed-citation>
          15.
          <string-name>
            <surname>AAVV</surname>
          </string-name>
          .
          <article-title>A review of cyber security risk assessment methods for SCADA systems</article-title>
          .
          <volume>10</volume>
          2015.
        </mixed-citation>
      </ref>
      <ref id="ref17">
        <mixed-citation>
          16.
          <article-title>-</article-title>
          .
          <article-title>Lo spazio cibernetico tra esigenze di sicurezza nazionale e tutela delle libertà individuali</article-title>
          .
          <source>Informazioni Difesa</source>
          .
          <year>2014</year>
          .
        </mixed-citation>
      </ref>
      <ref id="ref18">
        <mixed-citation>
          17.
          <string-name>
            <surname>Franchina</surname>
          </string-name>
          , Luisa. [Online] http://www.difesa.it/SMD_/CASD/IM/CeMiSS/Pubblicazioni/OSN/Documents/05_Franchina.pdf.
        </mixed-citation>
      </ref>
    </ref-list>
  </back>
</article>