        <article-title>Radiation of Biological Objects</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <string-name>Oleksiy Yanenko</string-name>
          <xref ref-type="aff" rid="aff0">0</xref>
          <xref ref-type="aff" rid="aff1">1</xref>
        </contrib>
        <contrib contrib-type="author">
          <string-name>Kostiantyn Shevchenko</string-name>
          <email>k.shevchenko@kpi.ua</email>
          <xref ref-type="aff" rid="aff0">0</xref>
          <xref ref-type="aff" rid="aff1">1</xref>
        </contrib>
        <contrib contrib-type="author">
          <string-name>Tatyana Klochko</string-name>
          <email>klochko_tr@ukr.net</email>
          <xref ref-type="aff" rid="aff0">0</xref>
          <xref ref-type="aff" rid="aff1">1</xref>
        </contrib>
        <contrib contrib-type="author">
          <string-name>Roman Tkachuk</string-name>
          <email>romantkachuk48@gmail.com</email>
          <xref ref-type="aff" rid="aff0">0</xref>
          <xref ref-type="aff" rid="aff2">2</xref>
        </contrib>
        <contrib contrib-type="author">
          <string-name>Vasyl Kuz</string-name>
          <email>vasylkuz1992@gmail.com</email>
          <xref ref-type="aff" rid="aff0">0</xref>
          <xref ref-type="aff" rid="aff2">2</xref>
        </contrib>
        <contrib contrib-type="author">
          <string-name>Workshop</string-name>
          <xref ref-type="aff" rid="aff0">0</xref>
        </contrib>
        <aff id="aff0">
          <label>0</label>
          <institution>(Peremogy)</institution>
          ,
          <addr-line>Kyiv, 03056</addr-line>
          ,
          <country country="UA">Ukraine</country>
        </aff>
        <aff id="aff1">
          <label>1</label>
          <institution>National Technical University of Ukraine "Ihor Sikorsky Kyiv Polytechnic Institute"</institution>
          ,
          <addr-line>37 Beresteyskyi Prospect</addr-line>
        </aff>
        <aff id="aff2">
          <label>2</label>
          <institution>Ternopil Ivan Puluj National Technical University</institution>
          ,
          <addr-line>Ruska str., 56, Ternopil, 46001</addr-line>
          ,
          <country country="UA">Ukraine</country>
        </aff>
      </contrib-group>
      <abstract>
        <p>The article deals with the problems of measuring weak microwave signals during studies of electromagnetic radiation (EMR) of biological objects. The authors proposed a variant of a highly sensitive radiometric system (RS) in the microwave range with modulation conversion of input signals, computer control of the operating mode and processing of measurement results. The use of a computer as part of the system provides the possibility of setting several modes of RS measurement: direct measurement of microwave radiation of a bioobject; comparison of the measured signal level with the reference value; adjustments of the frequency range during measurements; assessment of the presence of a nonequilibrium component in the radiation spectrum, as well as processing and storage of measurement results. To separate the thermal and non-equilibrium microwave components of EMF, an original hardware version of the metal-dielectric converter of the spectrum of the received signal has been developed. Studies were conducted on the selection of individual elements and the operation of the spectrum converter was described. An algorithm for converting input signals in a radiometric channel is proposed and described. The possibility of compensating the internal noise of the PC is shown, which provides the possibility of increasing the integral sensitivity up to 10-14...10-15 W. This, in turn, makes it possible to measure the non-equilibrium component of microwave radiation caused by the metabolic processes of biological objects. radiometric system Microwave radiation, biological objects, nonequilibrium radiation, metal-dielectric converter, Proceedings ITTAP'2023: 3rd International Workshop on Information Technologies: Theoretical and Applied Problems, November 22-24, Proceedings</p>
      </abstract>
    </article-meta>
  </front>
  <body>
    <sec id="sec-1">
      <title>1. Introduction</title>
      <p>
        The complexity of the task of estimating the non-equilibrium component of electromagnetic
radiation is due to the low signal level, which is comparable to the noise level of the radio-thermal
radiation of the objects under study. Various types of optical luminescence, microwave radiation of
biological structures, microorganisms, and other objects can serve as examples of non-equilibrium
EMR [
        <xref ref-type="bibr" rid="ref1 ref2">1, 2</xref>
        ].
      </p>
      <p>
        Living organisms, as well as any dielectric object with a temperature higher than that of the
environment, have radiothermal radiation of a wide spectrum. Part of the radiothermal radiation lies in
the microwave region of the spectrum [
        <xref ref-type="bibr" rid="ref3 ref4">3, 4</xref>
        ].
      </p>
      <p>The spectral power of such noise radiation correlates with temperature and is described by the
wellknown Nyquist formula:</p>
      <p>S  kT ,</p>
      <p>2020 Copyright for this paper by its authors.
CEUR</p>
      <p>ceur-ws.org
where: k – Boltzmann's constant ( k =1,38 1023 ); T - is the thermodynamic temperature of the object.</p>
      <p>At the temperature of a biological object, for example 309,6 К, a human body, the spectral power of
microwave radiation is S  4, 27·1021 W/Hz.</p>
      <p>The average noise electromagnetic radiation power is usually measured using a highly sensitive RS
in the frequency range limited by the bandwidth (analysis) of the radiometric channel f . The integral
electromagnetic radiation power of a heated body with radiative power  , which can be measured, is
determined by the expression:</p>
      <p>P  S  f ,T  f   kT f</p>
      <p>
        With the RS bandwidth f =108 Hz and the radiative capacity of the bioobject β = 0.75, the integral
power is P =3,2·10-13 W. The fluctuation threshold of RS sensitivity when measuring such small powers
should be 5...10 times lower than the measured signal. This causes certain problems when measuring
signals of this level [
        <xref ref-type="bibr" rid="ref5 ref6">5, 6</xref>
        ]. The authors managed to create RS, the sensitivity threshold of which is at
the level of 0,3·10-13 W [
        <xref ref-type="bibr" rid="ref5">5</xref>
        ].
      </p>
      <p>The system was used by the authors to study the electromagnetic properties of biomaterials. In this
work, RS with extended capabilities is considered, which can be used to isolate and measure the
parameters of non-equilibrium signals accompanying the metabolic processes of biological objects.</p>
      <p>
        Non-equilibrium radiation caused by the activity of biological objects, characterized by extremely
low intensity, will appear both in the optical and in the radio range. For their selection and assessment,
highly sensitive measuring equipment is used: spectrometers, microscopes, optical and microwave
radiometers, etc. Usually, the sensitivity of such equipment is limited by the thermal noise of the
environment. In addition, the total power of thermal and non-equilibrium electromagnetic radiation is
significantly less than the inherent noise power of modern electronic measuring equipment. The
radiation of bioobjects in the microwave range can also contain a non-equilibrium component, which
is stochastic and much weaker than radiothermal radiation. The allocation of this radiation presents a
certain complexity. There are various methods of extracting and measuring the non-equilibrium
component of electromagnetic radiation. For example, options for measuring non-equilibrium radiation
by isolating it from thermal stochastic noise are proposed. To do this, the radiation of living and
nonliving bioobjects is compared [
        <xref ref-type="bibr" rid="ref7">7, 8</xref>
        ]. At the same time, inanimate objects are heated to the temperature
that a living object has. This method is easily implemented in the study of fungi and microorganisms.
However, when studying high-level living organisms, for example, humans, it is unacceptable.
      </p>
      <p>The purpose of this work is to create a computerized highly sensitive radiometric system with
extended functionality for measuring weak signals in the microwave range of biological objects. Such
systems open up opportunities to more objectively conduct research on weak and emitted
electromagnetic fields in biology, medicine, materials science, physics, and other areas of science and
technology [9].</p>
    </sec>
    <sec id="sec-2">
      <title>2. Description of the structural scheme and design features of the RS</title>
      <p>In fig. 1 shows the structural diagram of the proposed highly sensitive RS with computer control of
the operating modes and the possibility of direct measurement of the non-equilibrium component of
microwave radiation.</p>
      <p>U1 PA1</p>
      <p>The scheme includes an input part consisting of a dual antenna X1 and X2, two pulse switching
modulators U1, U2, a tee A1 and a radiometric conversion channel. The output of the tee is connected
to the mixer U3 of the radiometric channel, which consists of a series-connected intermediate frequency
amplifier A2, a quadratic detector U4, a selective switching frequency filter Z1 with an amplifier A3, a
synchronous detector U5, a low-pass filter Z2, and a digital indicator PA1. The choice of the operating
frequency of the RS is carried out by the researcher, and it is implemented by the CPU computer by
generating the control voltage on the local oscillator G1. The operation of the switches is controlled by
rectangular pulses with a frequency of 1 kHz, which are also used as a reference for the synchronous
detector U5.</p>
      <p>The receiving combined RS antenna (Fig. 2, a) is made in the form of a rectangular horn 4, in which
two antennas are located - an open (measuring) antenna with a waveguide output 6 and a closed copper
foil (support) antenna with a waveguide output 5. The antennas are separated from each other by a
screen 7. The measuring antenna X1 ensures the passage of the full signal from the object of study. The
reference antenna X2 consists of a metal-dielectric converter of the spectrum of the received radiation
and ensures the allocation of the microwave power of the thermal component. The design of the support
antenna X2 includes a package of metal 1 and dielectric 2 plates located in a radio-transparent passive
thermostat 3.</p>
      <p>For direct measurement of microwave radiation of a biological object, a corresponding control
algorithm is installed in the computer. In this mode, only one X1 antenna and U1 modulator are used
in the "open-closed" mode. When the antenna is open, the radiometric channel receives a signal from
the biological object and noise from the input part of the RS. When the antenna is closed - only noise.
As a result, the difference between these signals is isolated at the output of the synchronous detector
U5 during the switching period, and the low-pass filter Z2 - the integral value of the measured EMR
bioobject, which is entered into the computer's memory and transmitted to the PA1 indicator.</p>
    </sec>
    <sec id="sec-3">
      <title>3. Description of the work of RS and the algorithm of transformation of nonequilibrium signals</title>
      <p>Isolation and measurement of the non-equilibrium component of bioobjects is a more complicated
procedure, which consists of the following.</p>
      <p>Antennas X1 and X2 (Fig. 1, a) of the measuring and reference channels are brought into contact
with the surface of the biological object under study. In general, a biological object generates
equilibrium (radiothermal) radiation and non-equilibrium (bioinformational) radiation. The
bioinformational component of electromagnetic radiation is generated by the cells of a living organism,
thanks to the metabolic processes occurring in living biological objects. According to the data of a
number of authors [10, 11], the non-equilibrium component of radiation performs a regulatory function
of the vital activity of cells, organs and the organism as a whole. The radiothermal component of
radiation is proportional to the body's absolute temperature and the coefficient of emissivity of each
layer. In the microwave range, the emitted signal contains both equilibrium and non-equilibrium
components. Therefore, the task of the proposed version of the radiometric system is to separate these
signals.</p>
      <p>The output signal power of the X1 mm-band antenna is proportional to the total intensity of both
radiated
(1)</p>
      <p>P1  S1IT  I 
where S1 - the sensitivity of the antenna; I T - is the intensity of radiothermal radiation; I –
nonequilibrium radiation intensity ( I  IT );.</p>
      <p>The input of the X2 antenna is covered by a screen, so direct reception of the object's microwave
radiation is impossible.</p>
      <p>However, due to the thermal contact of the X2 antenna screen with the surface of a living organism,
the screen heats up to the temperature of the surface area. Antenna X2 of the reference channel begins
to receive secondary radiothermal radiation from the inner surface of the dielectric plate through a
radiotransparent passive thermostat. Assuming that the emissivity of the screen with appropriate
selection and treatment of its surface is close to the emissive surface of the body, the output signal
power of the X2 antenna is proportional only to the intensity of radiothermal radiation</p>
      <p>P2  S1IT (2)</p>
      <p>Pulse modulators U1 and U2 work in the key mode (open-closed) and are controlled by anti-phase
voltages of low frequency, which are generated by the computer. If the modulator U1, made on
p-andn-diodes, is open, then the modulator U2 is similarly closed, and vice versa.</p>
      <p>Therefore, during one half-cycle of the low-frequency voltage, a signal with power is applied to the
input of the mixer U3 through the tee A1</p>
      <p>P3  K1S1IT  I  I R  (3)
where I R is the total intensity of the inherent noises of the mixer U3, generator G1 and intermediate
frequency amplifier A2, brought to the input of the mixer when the modulator U1 is open; K1 –
transmission coefficient of tee A1.</p>
      <p>Accordingly, in the next half-cycle of the low-frequency voltage, a signal with a power is sent to the
input of mixer U3 through tee A1</p>
      <p>P4  K1SIT  I R 
(4)
where I R - is the intensity of intrinsic noise when the modulator U2 of the reference channel is open.</p>
      <p>Since the receiving antennas X1 and X2 operate at the same temperature and have the same output
resistance, it can be assumed that the intensities of their own noises are I R  I R  I R .</p>
      <p>As a result of mixing the oscillating received signals with a wide spectrum and the oscillating
monochromatic signal of the G1 mm-band generator, an ensemble of oscillating difference frequencies
is created.</p>
      <p>If the frequency of the generator G1, performing the role of a local oscillator, is equal to f1 , then the
difference frequencies are created from the oscillating components of the emitted mm spectrum that
entered the frequency range:</p>
      <p>f 2  f1  f 4 ; f3  f1  f 4 , (5)
where f4 - is the central frequency of the narrowband amplifier A2 of the intermediate frequency.</p>
      <p>Within the bandwidth of the intermediate f4 frequency amplifier A2, the difference frequencies f5i
will be in the range
n f 4 (6)
 f5i  f 4 
i1 2
where the number n is determined by the bandwidth of the intermediate frequency amplifier.</p>
      <p>The power of the signal of the intermediate frequencies of equation (6), which consists of a set of
oscillations of the difference frequency, will be determined by the state of the modulators U1 and U2.</p>
      <p>During one of the half-cycles of the modulators, the signal power will be</p>
      <p>P6  K1K 2 S1S2 IT  I  I R P5 (7)
and during the second
where S3 is the sensitivity of the quadratic detector U4.</p>
      <p>From a sequence of video pulses with voltages and a low-frequency U1 , U 2 amplifier A3, an
alternating component is isolated and amplified, the amplitude of which is proportional to the polarity
of the voltage of the video pulses</p>
      <p>U 3( t )  K 3 U1  U 2 sign sin t (11)</p>
      <p>2
where K3 is the gain of the low-frequency amplifier A3;  is the circular frequency of the
lowfrequency generator, which is generated by the computer.</p>
      <p>The alternating voltage U 3( t ) is rectified by the synchronous detector U5 and smoothed by the
lowpass filter Z2. As the reference voltage of the synchronous detector U5, anti-phase voltages of the
lowfrequency generator G2 are used, each of which controls the modulators U1 and U2.</p>
      <p>The output voltage of the low-pass filter Z2, taking into account (9) and (10), has the form
1 (12)
U 4 </p>
      <p>K1K 2 K 3S1S 2 S3 P5 I
(10)
2
of electromagnetic radiation.</p>
      <p>Thus, the introduction of a reference channel with an internal source of secondary radiothermal
radiation provides direct measurement of the non-equilibrium component of radiation regardless of
intensity IT , i.e. thermal radiation of the investigated area of the skin of the object, and the level of
inherent noise I R of the receiving equipment.</p>
      <p>By retuning the frequency of the G1 generator in the microwave range, it is possible to measure the
intensity of the non-equilibrium component in various parts of the spectrum of the millimeter range.</p>
      <p>Some error in the measurement results occurs due to the difference in the coefficients of the radiation
capacity of each human or animal cover and the radiation of the inner surface of the metal screen of the
X2 antenna. To level such an error and increase the reliability of measurements of the non-equilibrium
component, the X2 antenna is made in the form of a rectangular horn (Fig. 2 a, b), in the middle of
which, on the side of the reference input, a metal-dielectric converter of the spectrum of the received
radiation is located. The converter is a two-layer package made of a metal plate and a plate of an organic
dielectric, connected to each other by heat-conducting glue or another method that ensures heat transfer
without losses.</p>
      <p>The fact is that the skin of a person and an animal differs in its emissivity from a completely black
body, the emissivity coefficient of which is   1. According to its properties, the skin belongs to the
class of gray bodies   1 , in which the radiative capacity is much greater than that of metals. The
studies carried out by the authors [12] showed that dielectrics made of organic materials are the closest
to each cover in terms  of the emissivity coefficient. The selection of materials with the help of a
thermal imager showed that ivory in the range of millimeter wavelengths has an emissivity close to the
emissivity of each cover (the difference does not exceed 5...7%). Therefore, an ivory plate is used in
the above device.</p>
      <p>Due to the good reflective ability and the appearance of the skin effect in the metal plate, both
components of electromagnetic radiation ( IT , I ) are reflected and scattered. For this, the thickness of
the metal plate is chosen to be 0,1...0,01 mm. To ensure good thermal contact with the object's skin, the
transducer is placed at the receiving end of a rectangular horn of a metal plate at the level of the antenna
end. The thickness of the dielectric plate is chosen to be 0,8...1 mm, which ensures its strength and rapid
heating from the metal plate. The heated dielectric plate begins to emit mm-waves of radiothermal
radiation, the intensity of which is close to the radiothermal radiation of a living organism. Ivory is a
"dead" object and does not form non-equilibrium radiation.</p>
    </sec>
    <sec id="sec-4">
      <title>4. Conclusions</title>
      <p>From the following conclusions can be drawn from this scientific work:</p>
      <p>The use of microprocessor technology to control the mode of operation of the developed radiometric
system significantly expands the functional measurement capabilities of the system and provides direct
measurement of microwave radiation of a bioobject, comparison of the measured signal level with a
reference value, adjustment of the research frequency, assessment of the presence of a non-equilibrium
component in the radiation spectrum, as well as processing and archiving of research results and
measurements.</p>
      <p>The high sensitivity of the RS is characterized by a significant fluctuation of the output signal, the
use of a computer allows to reduce this deficiency by digitizing and averaging the result, thereby
increasing the stability of the readings and the accuracy of the measurements.</p>
      <p>When studying microwave-irradiated biological objects, the sensitivity of the radiometric system
depends on their temperature and should be 5…10 times less than the level of the signal under
investigation. For the analysis of signals of the human body, the authors recommend choosing this ratio
within 5...10 times, and the sensitivity at the level of reliable measurement of body thermal radiation of
0,3·10-13 W.</p>
      <p>The given values of РС sensitivity and its relationship with thermal microwave radiation make it
possible to detect the presence of non-equilibrium radiation, which is 5...8 times less than the level of
the total radiation of the bioobject.</p>
      <p>The intensity of non-equilibrium radiation is largely an indicator of its vitality.</p>
      <p>Non-equilibrium radiation can be used in medical practice as a diagnostic parameter, in agriculture
as an indicator of the biological activity of seeds and embryos, in the food industry to control the
ripening of hard cheese, wine and other products associated with the use of microorganisms and
bioengineering technologies.</p>
    </sec>
    <sec id="sec-5">
      <title>5. References</title>
      <p>[8] Patent No. 66419 (Ukraine), G01N22/00, G01J5/00. A method of estimating the excess of
secondary microwave radiation over radiothermal radiation / Yu.A. Skrypnyk, A.F. Yanenko, V.P.</p>
      <p>Kutsenko. - Application 18.12.2002; Publ. 17.05.2004; Bul. No. 5.
[9] Yanenko O.P., Shevchenko K.L., Kychak V.M. "Methods and means of formation, processing and
use of low-intensity electromagnetic signals" // Monograph. Kind. VNTU- Vinnytsia: 2020- 268
pages.
[10] Sitko S.P. Physics of Alive - the New Trend of Fundamental Natural Science// Physics of Alive.
2000. - Vol. 8, No. 2. P. 5-13.
[11] Gilbert N. Ling. A Revolution in the Physiology of the Living Cell. Michigan, Krieger Publication</p>
      <p>Company. - 1992. 378 p.
[12] O. Yanenko, K. Shevchenko, S. Peregudov, V. Malanchuk, V. Shvydchenko, O. Golovchanska.</p>
      <p>Method for Determining the Electromagnetic Compatibility of Biomaterials/ ITTAP'2022: 2nd
International Workshop on Information Technologies: Theoretical and Applied Problems,
November 22–24, 2022, Ternopil, Ukraine. P. 376-380.</p>
    </sec>
  </body>
  <back>
    <ref-list>
      <ref id="ref1">
        <mixed-citation>
          [1]
          <string-name>
            <surname>Levshin</surname>
            <given-names>L.V.</given-names>
          </string-name>
          ,
          <string-name>
            <surname>Saletskyi</surname>
            <given-names>A.M. Luminescence</given-names>
          </string-name>
          <article-title>and its measurement: Molecular luminescence</article-title>
          . Moscow: Izd-vo Moscow State University. 1989-
          <fpage>272p</fpage>
          .
        </mixed-citation>
      </ref>
      <ref id="ref2">
        <mixed-citation>
          [2]
          <string-name>
            <surname>Basharinov</surname>
            <given-names>A. E.</given-names>
          </string-name>
          ,
          <string-name>
            <surname>Tuchkov</surname>
            <given-names>L. T.</given-names>
          </string-name>
          ,
          <string-name>
            <surname>Polyakov</surname>
            <given-names>V. M.</given-names>
          </string-name>
          ,
          <string-name>
            <surname>Ananov</surname>
            <given-names>N. I.</given-names>
          </string-name>
          <article-title>Measurement of radiothermal</article-title>
          and plasma radiation // M.: Sov. radio - 1968. - P.
          <fpage>390</fpage>
        </mixed-citation>
      </ref>
      <ref id="ref3">
        <mixed-citation>
          [3]
          <string-name>
            <surname>Panagopoulos</surname>
            ,
            <given-names>D.J.</given-names>
          </string-name>
          ,
          <string-name>
            <surname>Balmori</surname>
            ,
            <given-names>A.</given-names>
          </string-name>
          <article-title>On the biophysical mechanism of sensing atmospheric discharges by living organisms</article-title>
          .
          <source>The Science of the Total Environment</source>
          ,
          <fpage>599</fpage>
          -
          <lpage>600</lpage>
          ,
          <year>2017</year>
          ,
          <fpage>2026</fpage>
          -
          <lpage>2034</lpage>
          , doi:10.1016/j.scitotenv.
          <year>2017</year>
          .
          <volume>05</volume>
          .089.
        </mixed-citation>
      </ref>
      <ref id="ref4">
        <mixed-citation>
          [4]
          <string-name>
            <surname>Yashin</surname>
            <given-names>A.A.</given-names>
          </string-name>
          <article-title>Information-field self-organization of biosystems // Bulletin of new medical technologies</article-title>
          . -
          <string-name>
            <surname>Tula</surname>
          </string-name>
          . -
          <year>2000</year>
          . - Vol.
          <volume>7</volume>
          , No. 1. - P.
          <fpage>30</fpage>
          -
          <lpage>38</lpage>
        </mixed-citation>
      </ref>
      <ref id="ref5">
        <mixed-citation>
          [5]
          <string-name>
            <given-names>O.</given-names>
            <surname>Yanenko</surname>
          </string-name>
          ,
          <string-name>
            <given-names>K.</given-names>
            <surname>Shevchenko</surname>
          </string-name>
          ,
          <string-name>
            <given-names>V.</given-names>
            <surname>Malanchuk</surname>
          </string-name>
          ,
          <string-name>
            <surname>O.</surname>
          </string-name>
          <article-title>Golovchanska/ Microwave Evaluation of Electromagnetic Compatibility of Dielectric Remedial and Therapeutic Materials with Human Body</article-title>
          .
          <source>International Journal of Materials Besearch, USA</source>
          ,
          <year>2019</year>
          , Vol.
          <volume>7</volume>
          , No.
          <issue>1</issue>
          , pp.
          <fpage>37</fpage>
          -
          <lpage>43</lpage>
          .
        </mixed-citation>
      </ref>
      <ref id="ref6">
        <mixed-citation>
          [6]
          <string-name>
            <surname>Bhatt</surname>
            ,
            <given-names>C.R.</given-names>
          </string-name>
          ,
          <string-name>
            <surname>Redmayne</surname>
            ,
            <given-names>M.</given-names>
          </string-name>
          ,
          <string-name>
            <surname>Abramson</surname>
            ,
            <given-names>M.J.</given-names>
          </string-name>
          ,
          <string-name>
            <surname>Benke</surname>
            ,
            <given-names>G.</given-names>
          </string-name>
          <article-title>Instruments to Assess and Measure Personal and Environmental Radiofrequency-Electromagnetic Field Exposures</article-title>
          .
          <source>Australasian Physical &amp; Engineering Sciences in Medicine</source>
          ,
          <volume>39</volume>
          ,
          <year>2016</year>
          ,
          <fpage>29</fpage>
          -
          <lpage>42</lpage>
          , doi:10.1007/s13246-015-0412-z
        </mixed-citation>
      </ref>
      <ref id="ref7">
        <mixed-citation>
          [7]
          <string-name>
            <given-names>Patent</given-names>
            <surname>No</surname>
          </string-name>
          .
          <volume>56208</volume>
          (Ukraine).
          <article-title>The method of measuring the bioinformational component of electromagnetic radiation and the device for its detection / S. P</article-title>
          . Sitko,
          <string-name>
            <surname>Yu</surname>
            .
            <given-names>O.</given-names>
          </string-name>
          <string-name>
            <surname>Skrypnyk</surname>
            ,
            <given-names>O. P.</given-names>
          </string-name>
          <string-name>
            <surname>Yanenko - Byul</surname>
          </string-name>
          . 5. -
          <fpage>2003</fpage>
          .
        </mixed-citation>
      </ref>
    </ref-list>
  </back>
</article>