        <article-title>Automatic Detection of a Heart ROI in Perfusion MRI Images</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <string-name>Lennart Tautz</string-name>
          <email>lennart.tautz@mevis.fraunhofer.de</email>
          <xref ref-type="aff" rid="aff1">1</xref>
        </contrib>
        <contrib contrib-type="author">
          <string-name>Ola Friman</string-name>
          <xref ref-type="aff" rid="aff1">1</xref>
        </contrib>
        <contrib contrib-type="author">
          <string-name>Anja Hennemuth</string-name>
          <xref ref-type="aff" rid="aff1">1</xref>
        </contrib>
        <contrib contrib-type="author">
          <string-name>Achim Seeger</string-name>
          <xref ref-type="aff" rid="aff0">0</xref>
        </contrib>
        <contrib contrib-type="author">
          <string-name>Heinz-Otto Peitgen</string-name>
          <xref ref-type="aff" rid="aff1">1</xref>
        </contrib>
        <aff id="aff0">
          <label>0</label>
          <institution>Eberhard Karls University</institution>
          ,
          <addr-line>Tubingen</addr-line>
        </aff>
        <aff id="aff1">
          <label>1</label>
          <institution>Fraunhofer MEVIS</institution>
          ,
          <addr-line>Bremen</addr-line>
        </aff>
      </contrib-group>
      <fpage>259</fpage>
      <lpage>263</lpage>
      <abstract>
        <p>This work presents an automatic and robust approach to detect the heart region in MRI perfusion images. Intensity variance is used to identify high variability regions, which are in turn ltered with features based on their shape and position. The approach is validated using 44 clinical data sets against a ground truth generated by experts. Coronary heart disease is a major cause of death, making the detection of functional disorders of the heart muscle (myocardium) a task of high clinical value. Myocardial perfusion can be measured with MR imaging. To this end, an image sequence is acquired with high temporal resolution showing the pass of an administered contrast agent through vessels and myocardial tissue (Fig. 1). The images encompass a region substantially larger than the heart region to be analyzed. Image processing steps such as histogram analysis or registration can be disturbed by unrelated information from areas outside the heart. If a region of interest (ROI) containing only the heart is available, further processing steps can be restricted to the relevant regions and performed in shorter time. We propose an automatic approach that combines knowledge about the anatomy and the acquired image to detect the heart ROI. Related approaches exist for the detection of the heart in cine MRI sequences. In recent work [1], the use of intensity variance over time to construct a ROI in cine MRI sequences is proposed. The presented approach does, however, assume that RV and LV can be unambiguously identified in the variance image, which</p>
      </abstract>
    </article-meta>
  </front>
  <body>
    <sec id="sec-1">
      <title>Introduction</title>
      <p>
        Heart
does not take into account that in contrast-enhanced images other structures,
such as the kidney, vessels or artifacts, can show similar variability. We propose
a similar approach that is more robust with respect to disturbances from
artifacts and other contrast agent-influenced structures. The authors of [
        <xref ref-type="bibr" rid="ref2">2</xref>
        ] create a
motion map based on intensity differences, which is sensitive to high variability.
An alternative approach that uses FFT to characterize intensity variability and
to delineate cardiac structures in 4D MRI images is presented in [
        <xref ref-type="bibr" rid="ref3">3</xref>
        ]. Spreeuwers
et al. [
        <xref ref-type="bibr" rid="ref4">4</xref>
        ] search for local maxima in space and time to detect left and right
ventricle (LV and RV) in perfusion MRI sequences, but the authors do not explain
how they assure that the ROI contains the heart at all timepoints.
2
2.1
      </p>
    </sec>
    <sec id="sec-2">
      <title>Materials and Methods</title>
      <sec id="sec-2-1">
        <title>Data</title>
        <p>For testing, 44 perfusion data sets are used. The data have three to four
shortaxis slices with about 8 mm thickness, an in-plane-resolution of 1.6 to 2.1 mm2,
and a gap of up to 24 mm. The images were acquired with a an ECG-triggered
SSFP sequence. Each time sequence consists of 40 images, with an sampling
interval of about 1 s. Because of the large gap between slices, the data can be
processed as a set of several 2D+time slices. The geometric connection between
the slices is in this work exploited in a second step to ensure consistency.
2.2</p>
      </sec>
      <sec id="sec-2-2">
        <title>Processing pipeline rationale</title>
        <p>The ROI detection is based on the temporal behavior of image values.
Cardiac motion and contrast-enhanced blood flow will produce high variability of
intensity values over time inside the heart region. In addition to the ventricles,
the kidney and other vessels can be present in the image and will exhibit
similar intensity curves over time. Because the LV consistently produces a round
region in the variance image, it allows for a more robust heart detection than
the RV. Comparing LV-specific features for candidate areas extracted by a
connected component analysis, non-LV areas can be discarded. This ROI containes
only LV and RV areas and determines a bounding box around the heart for the
whole sequence. Steps 1 and 2 of the pipeline are executed for each slice of the
2D+time data set, and steps 3 and 4 merge the preceding results.
Step 1: Temporal Variance. The standard deviation of the intensity over
time is calculated (Fig. 2b). The result is thresholded with the value at the
97percentile, retaining only regions with very high variability (Fig. 2c). To remove
small holes and false-positives caused by noise, a 3 3 median filter is applied.
Step 2: Candidate Regions. The candidates for the LV region are then
extracted by a connected components analysis. A lower boundary for the
component volume of 3 ml has been to empirically determined to exclude remaining
small regions and vessels outside the heart. Usually, three to five high variability
regions will remain, including the LV region, up to two RV regions due to the size
and flow behavior of the right ventricle, the kidney and smaller vessels (Fig. 2d).
For each of these candidates, two features are calculated: the similarity to an
ellipse fitting in the candidate’s bounding box, and the distance of the candidate
to the image center. The similarity to an ellipse is defined as the Jaccard index
J between the area Aellipse of the ellipse and the area Acandidate of the convex
hull of the candidate</p>
        <p>J (Aellipse; Acandidate) = jAellipse \ Acandidatej
jAellipse [ Acandidatej
(1)
If the aspect ratio of the candidate is below 0.5, the candidate is discarded. The
distance to center is defined as the inverse scaled distance between the image
center and the candidate’s center. The distance is inversely scaled to a value
between 0 and 1, where 1 is the minimal distance, and 0 is the maximal distance
between the image center and one of the image corners. These two feature
scores are added together, and the candidate with the maximal score is selected
as the LV region for the current slice (Fig. 2e). A bounding box is computed
around this region and extended by 30 mm on each side to reflect the fact that
(a) Input image
(b) Std. Dev. image
(c) High std. dev. regions
(d) LV candidates
(e) Best LV candidate</p>
        <p>(f) Final result
the candidate ROI represents the LV bloodpool without the myocardium. To
include the myocardium and a small safety margin, the bounding box must be
extended by the typical myocardium thickness.</p>
        <p>Step 3: 3D Consistency. When the LV regions have been determined for all
2D slices in the data set, a 3D consistency check is carried out. On single slices, a
different region, typically located in the kidney, can obtain the highest score. To
remove such outliers, the positions of all regions are compared. Because the true
LV regions are assumed to be centered around the long axis, the distance between
regions must not exceed 40 mm, allowing for movement and errors introduced
by the variability analysis. If a region lies farther away, a new region is selected
for this slice. This is repeated until a valid region is found.</p>
        <p>Step 4: Bounding box. A bounding box that encompasses the LV in all slices
is obtained by calculating the union of the slice bounding boxes. Because this
box is determined mainly by information from the center of the LV region, it
will not be large enough to contain the moving LV over time. The RV region
will usually not be connected to the LV region, so that the box will not cover the
heart fully. This is compensated for by stretching the bounding box by a factor
of 0.75 into the direction of the RV. The stretching factor reflects a simplified
diameter relation of LV and RV. The relative position of the RV can be inferred
from the image orientation, assuming standard heart anatomy (Fig. 2f).
3</p>
      </sec>
    </sec>
    <sec id="sec-3">
      <title>Results</title>
      <p>The algorithm was applied to find the heart ROI in all test data sets. Examples
are shown in Fig. 3. The detection takes less than one second per data set on a
standard PC with a 3 GHz CPU and 8 GB memory.</p>
      <p>The calculated ROIs were quantitatively evaluated against ground truth
ROIs determined manually by three experts. For each data set, the average
of the manually drawn ROIs was taken as ground truth and compared with
the automatically identified ROI. The automatic ROI was deemed correct if the
manual ROI was fully contained by it. If it was not, the maximum difference
between the ROI borders was calculated. In 40 of 44 data sets, the ROI was
calculated correctly by our approach. In the remaining four data sets, the
maximum distance between the manual ROI and the automatic ROI was 6 mm, with
a mean of 4 mm. Examples of bounding boxes are shown in Fig. 3.
4</p>
    </sec>
    <sec id="sec-4">
      <title>Discussion</title>
      <p>Our approach provides an automatic and robust method to determine a ROI
of the heart in cardiac perfusion MRI images. The ROI detection forms a
preprocessing step for further analysis, for instance segmentation of the myocardium
and motion correction in the time sequence. Because the detection relies on the</p>
      <p>(a) Correct ROI
(b) Correct ROI
(c) Correct ROI
(d) Correct ROI
(e) Failed ROI
(f) Failed ROI
detection of the LV, perfusion data of hearts with congenital defects can be
processed with this method as well.</p>
      <p>Because the ROI can be rather large in comparison to the true heart region
due to conservative expansion, future work will focus on downsizing overly large
ROIs. This will require a detection of the RV region among the region
candidates and a detection of the borders in the heart region. A combination of this
information will allow the method to calculate a tighter bounding box without
sacrificing correctness at critical points.</p>
    </sec>
  </body>
  <back>
    <ref-list>
      <ref id="ref1">
        <mixed-citation>
          1.
          <string-name>
            <surname>Zambal</surname>
            <given-names>S</given-names>
          </string-name>
          , Schollhuber
          <string-name>
            <given-names>A</given-names>
            ,
            <surname>Buhler K</surname>
          </string-name>
          , et al.
          <article-title>fast and robust localization of the heart in cardiac MRI series</article-title>
          .
          <source>Proc VISAPP</source>
          .
          <year>2008</year>
          ;
          <volume>1</volume>
          :
          <issue>341</issue>
          {
          <fpage>6</fpage>
          .
        </mixed-citation>
      </ref>
      <ref id="ref2">
        <mixed-citation>
          2.
          <string-name>
            <surname>Pednekar</surname>
            <given-names>A</given-names>
          </string-name>
          ,
          <string-name>
            <surname>Kurkure</surname>
            <given-names>U</given-names>
          </string-name>
          ,
          <string-name>
            <surname>Muthupillai</surname>
            <given-names>R</given-names>
          </string-name>
          , et al.
          <source>Automated left ventricular segmentation in cardiac MRI. IEEE Trans Biomed Eng</source>
          .
          <year>2006</year>
          ;
          <volume>53</volume>
          (
          <issue>7</issue>
          ):
          <volume>1425</volume>
          {
          <fpage>8</fpage>
          .
        </mixed-citation>
      </ref>
      <ref id="ref3">
        <mixed-citation>
          3.
          <string-name>
            <surname>Lin</surname>
            <given-names>X</given-names>
          </string-name>
          ,
          <string-name>
            <surname>Cowan</surname>
            <given-names>B</given-names>
          </string-name>
          ,
          <string-name>
            <surname>Young</surname>
            <given-names>A</given-names>
          </string-name>
          .
          <article-title>Automated detection of the left ventricle from 4D MR images: validation using large clinical datasets</article-title>
          .
          <source>Adv Image Video Technol</source>
          .
          <year>2006</year>
          ; p.
          <volume>218</volume>
          {
          <fpage>27</fpage>
          .
        </mixed-citation>
      </ref>
      <ref id="ref4">
        <mixed-citation>
          4.
          <string-name>
            <surname>Spreeuwers</surname>
            <given-names>L</given-names>
          </string-name>
          ,
          <string-name>
            <surname>Breeuwer</surname>
            <given-names>M.</given-names>
          </string-name>
          <article-title>Automatic detection of myocardial boundaries in MR cardio perfusion images</article-title>
          .
          <source>Med Image Comput Comput Assist Intervent</source>
          .
          <year>2001</year>
          ; p.
          <volume>1228</volume>
          {
          <fpage>31</fpage>
          .
        </mixed-citation>
      </ref>