      <abstract>
        <p>-The present paper discusses the issues arising from the need of presenting to the user information about the environmental impact of their applications in a cloud environment. Several aspects have to be considered: to make aware the users of the energy consumption and environmental impact of their applications, but also to make them aware about the actions taken in the environment with the goal of satisfying non functional requirements and optimizing the energy consumption and environmental impact of applications.</p>
      </abstract>
    </article-meta>
  </front>
  <body>
    <sec id="sec-1">
      <title>I. INTRODUCTION</title>
      <p>Energy consumption and the environmental impact of
applications running in clouds are being studied from different
points of view. In the ECO2Clouds project1 the focus is on
providing an optimized environment, taking actions during the
execution of applications in the clouds, both at the
infrastructural and at the application level.</p>
      <p>In this short paper, we focus on how to present the
information to the users about the energy consumed and the
environmental impact expressed in terms CO2 emissions. The
ability of showing to the users the consumption of their
applications derives from an existing monitoring infrastructure
and the availability of information about the energy mix in the
sites where the clouds infrastructure is available. This problem
has a general nature, in fact, it is a possible case of the more
general case of presenting to users the environmental impact
of applications and also of showing them how this impact
can be reduced and which actions are taken, or can possibly
be taken, to achieve this goal. In their seminal paper [?]
Watson and Boudreau discuss the implications of monitoring
and controlling energy consumption in controllable systems,
with the goal of reducing energy consumption. The problem
has a general nature and possible solutions valid in a given
field, could be applied also in other fields. In the present paper
we focus on presenting energy consumption and environmental
impact in so called eco-reports, containing useful information
for the users to assess their environmental impact, to
understand optimization actions undertaken by the system they are
using, and to take decisions on the basis of this information.
The approach is based on the ECO2Clouds project [?], which
focuses on environmental impact of federated clouds and
provides a monitoring infrastructure for assessing eco-metrics
[?] and possible for reducing the CO2 emissions.</p>
      <p>In the following sections, we first present the ECO2Clouds
approach for presenting environmental impact of applications
in Section 2, then we discuss awareness reports and adaptivity
reports in Sections 3 and 4 respectively.</p>
      <p>II.</p>
    </sec>
    <sec id="sec-2">
      <title>ARCHITECTURE AND INFRASTRUCTURE REQUIREMENTS</title>
      <p>In the ECO2Clouds project the goal is to improve energy
efficiency and to reduce the environmental impact of
applications. Eco-reporting is achieved in two ways:</p>
      <p>Awareness reporting: showing the users information
about the execution of their applications, including
values of eco-metrics.</p>
      <p>Adaptivity reporting: describing how the platform
applied adaptivity actions to improve the energy
efficiency and reduce the environmental impact of
applications, showing for each decision taken by the system
the motivations for the actions.</p>
      <p>In Fig. 1 we show the architecture that enables this approach.
This general architecture shows that the reporting is based on
the interaction with a cloud ecosystem which is providing
monitored eco-metrics (left arrow) and information about
adaptivity actions (right arrow). The latter includes not only
information about the action itself, but also motivations for
taking it in a given context. In order to provide environmental
impact information, the cloud ecosystem must also be based
on information given by energy providers about the current
energy mix being provided. Such a general architecture can be
adopted also in other contexts, thus not being limited to cloud
computing, but it can be generalized to all those cases in which
the reduction of the environmental impact is a combination of
automatic actions performed by an adaptive and optimizing
infrastructure and human decisions, based on the awareness
on energy consumption given to the users by reports on
ecometrics.</p>
      <p>III.</p>
    </sec>
    <sec id="sec-3">
      <title>AWARENESS REPORT This section focuses on how the data to be presented to the user can be obtained.</title>
      <sec id="sec-3-1">
        <title>A. Environmental impact of the cloud site</title>
        <p>In the cloud scenario, one of the important choices for the
deployment of an application is the selection of the cloud site.</p>
        <p>Such decision usually takes into consideration factors as the
state of the machines and their average performance. In order
to decrease the environmental impact of the applications, we
also consider energy-related indexes such the percentage of
Copyright c papers’ authors. Copying permittedonly for private and academic purposes. This volume is published and copyrighted by its editors
green energy sources used by the site and the carbon emission
factors. In order to retrieve such data, it is fundamental to know
the energy mix that the sites are using, that is the type of the
exploited energy sources together with the average percentage
of provided power. In fact, the evaluation of the CO2 emissions
is based on the emission factors ef (gCO2e/kWh) that depend
on the type of considered energy source. If the i th cloud
site is powered by more than one energy source, the emission
factor efi results:
efi =</p>
        <p>X
s2sources</p>
        <p>efs ess;i
where efs is the emission factor related to the s th energy
source while ess;i is the percentage of utilization of the s th
energy source.</p>
        <p>The energy mix (and thus the percentages ess;i) can be
easily determined if the data center is powered by dedicated
energy sources while it might be difficult to be calculated if
the data center is powered by the national grid. In this latter
case, we have to find information about the national energy
provision. We might rely on public documents that periodically
provide national average emission factors or on the web sites of
some countries (e.g., France and UK) that provide the real time
energy mix. Accessing accurate and real time values allows us
to perform a more useful and comprehensive assessment and
analysis of the cloud site CO2 emissions. The availability of
historical data can be exploited in order to identify regular
and/or seasonal patterns that can be used in the deployment of
applications.</p>
      </sec>
      <sec id="sec-3-2">
        <title>B. Computing the CO2 emissions</title>
        <p>Given the emission factor of each site in a given moment,
the computation of the CO2 emissions related to the execution
of an application running in a cloud environment can be
obtained by the following formula:</p>
        <p>X
i2site</p>
        <p>Z</p>
        <p>t
CO2e =</p>
        <p>efi(t) P app(t) dt
where P app represents the power consumed by an application
obtained as the sum of power consumed by the j th virtual
machines assigned to the application and running on the host
k th installed in site i th:</p>
        <p>P app(t) =</p>
        <p>X</p>
        <p>X
i2site k2hosts</p>
        <p>Pjv;mk;i(t)</p>
        <p>Starting from this premise, how to compute the power
required by an application becomes the central and most
problematic point. Indeed, the only place where the power
can be physically measured is at host level where many
applications are running. At the higher level, i.e., virtualization,
the application can be identified as the user of some VMs
but the power of such VMs can be only estimated. Moreover,
as could-based applications might run on different VMs that,
in turn, involve several physical host the computation of the
power needs to take care of the possible heterogeneity among
the different severs installed on the sites.</p>
        <p>The approach proposed in this paper starts from the
assumption that a positive correlation between the CPU load
and the power consumption exists at both physical and
virtualization level, as also demonstrated in [?]. Based on this,
we monitor the CPU load and the power consumption of each
k th host in a site i th, i.e., Ckh;i and Pkh:i. This data are
measured and not computed so they are reliable by definition.
Collecting the values of Ckh;i and Pkh:i allows us to identify
the relationship of these two variables. An important aspect
concerns the min and max values that these two variables
can assume. Indeed, while Ckh;i 2 [0::100%], the Pkh;i =
[min; max] where min 2 R0+; maxmin 2 R0+; min max
and the range vary from host to host as it depends on the
architecture and the hardware components. On this basis, Pkh;i
can be divided into two components:</p>
        <p>Pkh;i(t) = P idlekh;i + P execkh;i(t)
where the first element represents the power consumed by the
when Ckh;i ' 0, i.e., the host is inactive. The second element
varies during the time based on the CPU load according to
a function f that captures the dependency between the CPU
load and the power based on the analysis of the monitoring
values.</p>
        <p>Moving to the virtualization layer, we can measure, for
each j th VM (deployed on a k th host) used by the
application, the CPU load Cjv;mk;i. This can be done looking to
either the system tools inside the VMs (e.g. top command) or
the monitoring system provided by the hypervisor. Finally, the
power of a VM is given by the following formula:
Pjv;mk;i =</p>
        <p>P idlekh;i
#V Mk</p>
        <p>f (P execkh;i; Cjv;mk;i)</p>
        <p>It has to be noted that the awareness module can help
the users assessing not only the environmental impact of the
applications as they are running, but also to support evaluations
of possible shifts in time of the execution of the application.
In fact, assuming that the energy computed by the VMs is
available, the total value of emissions can change depending
on when the application is started, since the emission factor
of a site is variable in time. The users can thus assess if it is
convenient to delay the execution of an application to exploit
reduced emission factors at other times of the day.</p>
        <p>IV.</p>
        <p>ADAPTATION REPORT AND THE FINAL ANALYSIS</p>
        <p>REPORT</p>
        <p>In this section we discuss the Final Analysis Report, which
is an instrument provided to the user allowing a detailed
analysis of his experiments. The aim of this report is to show to
the user some information about the behavior of the terminated
experiments.</p>
        <p>At the end of an experiment the user can access the Final
Analysis Report, showing a summary of the behavior of the
experiment. This summary is divided into three sections: the
“Details” section, the “Eco Report” section, and the
“Adaptation Report” section.</p>
        <p>The “Details” section includes a general summary of the
experiment consisting in some general information.
Information consists in the ID of the experiment, start time of the
experiment which consists in the moment when the experiment
has started, and end time, which is the time stamp when the
experiment has been completed. Finally, the last part contains
also the list of the VMs involved in the experiment with their
IDs.</p>
        <p>The second section is the “Eco Report”. This section gives
an overview of the behavior of the experiment, giving some
general information about the sustainability of the experiment
in terms of energy consumption and CO2 emissions. This
information is given for the whole experiment with e general
value aggregating the impact of all the components of the
experiment involved in CO2 emissions, and for each VM, from
the creation to the expiration. This first analysis is useful to
make the user aware in an immediate and easy to understand
way of the impact of his experiments. An example of the “Eco
Report” is shown in Fig. 2.</p>
        <p>During the execution of an experiment, some aspects of
the system can misbehave decreasing the performance of the
experiment or increasing the environmental impact of its
execution. The system administrator can perform some adaptation
actions in order to fix these misbehavior. The last section of the
Final Analysis Report, the “Adaptation Report”, contains some
information about what has been done for improving the state
of the system, during the lifetime of the whole experiment.
The report consists in a list of adaptation actions with the
time stamp of enactment and a description. Selecting one of
the actions in the list, the user can have additional information
about the triggers of the selected adaptation action. Triggers
are usually the violation of the constraints about the values that
each metric can take. An example of the Adaptation Report
section is shown in Fig. 3, where three actions has been enacted
during the execution of the experiment, and the first action
(switch off of a VM) has been executed to reduce the power
consumption of the experiment.</p>
        <p>The user can also access to a more detailed
information about his experiments, called “Metric Report”. Each
experiment is monitored using a monitoring system collecting
information about several aspects of its behavior. The collected
metrics can be directly or indirectly related to the efficiency
of the experiment, but also to the quality of service, which is
an important information for the user. The user can analyze
one by one the collected metrics to evaluate the behavior of
its experiment and to make considerations about improvements
and future deployments. An example of the Metric Report can
be observed in Fig. 4. Information is shown at three granularity
levels: (i) the infrastructure level; (ii) the virtual machine level;
and (iii) the application level.</p>
        <p>At the infrastructure level, the user can select a site and
then one of the hosts in the site. Selecting the host, the list of
collected metrics for the host can be seen. When clicking on
one of the metrics, the user can read the list of the collected
values and a graphical representation of the trend of the metric.
The user can also select a time slot using the zoom at the
bottom of the graph. Examples of metrics at the infrastructure
level are resources utilization (CPU, memory, and IOPS),
number of running VM, and power consumption of the host.</p>
        <p>The VM level shows similar metrics but for the VMs
involved in the experiment. From the list of VMs, the user
can select a VM and can observe the behavior of the metrics
collected for it. Example of metrics are resources utilization
(CPU, memory, and IOPS) and power consumption from the
VM perspective.</p>
        <p>The last level, the application, contains metrics collected
to measure the environmental impact and the performance of
the application. The user can see both metrics aggregated for
the whole application and for the specific activities of the
application. Example of metrics are response time (time to
serve a request), throughput (number of transactions executed),
and application performance (ratio between the number of
transactions executed and the energy consumed).</p>
        <p>Information contained in the Final Report Analysis is
necessary to make the user aware of the ecological impact of
his experiments. Moreover, the user can use this information
to take informed decision about how to deploy and set further
executions of his experiment in order to make them more
sustainable or more efficient.</p>
        <p>V.</p>
        <p>CONCLUDING REMARKS</p>
        <p>The present paper presents a general approach to
visualize energy and environmental information for applications
in eco-reports. The approach distinguishes between awareness
information and information about the actions that have been
performed by the system to keep it compliant with the given
requirements. The approach has been developed for a federated
cloud system, however its eco-reports can be applied in more
general settings, in which the system is able to report on
ecometrics and is able to provide an active behaviour to maintain
given constraints.</p>
      </sec>
    </sec>
    <sec id="sec-4">
      <title>ACKNOWLEDGMENTS</title>
      <p>This work has been supported by the ECO2Clouds project
(http://eco2clouds.eu/) and has been partly funded by the
European Commission’s IST activity of the 7th Framework
Program under contract number 318048.</p>
    </sec>
  </body>
  <back>
    <ref-list>
      <ref id="ref1">
        <mixed-citation>
          [1]
          <string-name>
            <given-names>R. T.</given-names>
            <surname>Watson</surname>
          </string-name>
          , M.-C.
          <article-title>Boudreau, and</article-title>
          <string-name>
            <given-names>A. J.</given-names>
            <surname>Chen</surname>
          </string-name>
          , “
          <article-title>Information systems and environmentally sustainable development: Energy informatics and new directions for the is community</article-title>
          ,
          <source>” MIS Quarterly</source>
          , vol.
          <volume>34</volume>
          , no.
          <issue>1</issue>
          , pp.
          <fpage>23</fpage>
          -
          <lpage>38</lpage>
          ,
          <year>2010</year>
          .
        </mixed-citation>
      </ref>
      <ref id="ref2">
        <mixed-citation>
          [2]
          <string-name>
            <given-names>U.</given-names>
            <surname>Wajid</surname>
          </string-name>
          ,
          <string-name>
            <given-names>B.</given-names>
            <surname>Pernici</surname>
          </string-name>
          , and G. Francis, “
          <article-title>Energy efficient and CO2 aware cloud computing: Requirements and case study,” in IEEE SMC</article-title>
          , pp.
          <fpage>121</fpage>
          -
          <lpage>126</lpage>
          ,
          <year>2013</year>
          .
        </mixed-citation>
      </ref>
      <ref id="ref3">
        <mixed-citation>
          [3]
          <string-name>
            <given-names>C.</given-names>
            <surname>Cappiello</surname>
          </string-name>
          ,
          <string-name>
            <given-names>S.</given-names>
            <surname>Datre</surname>
          </string-name>
          ,
          <string-name>
            <given-names>M.</given-names>
            <surname>Fugini</surname>
          </string-name>
          ,
          <string-name>
            <given-names>P.</given-names>
            <surname>Melia</surname>
          </string-name>
          ,
          <string-name>
            <given-names>B.</given-names>
            <surname>Pernici</surname>
          </string-name>
          ,
          <string-name>
            <given-names>P.</given-names>
            <surname>Plebani</surname>
          </string-name>
          ,
          <string-name>
            <given-names>M.</given-names>
            <surname>Gienger</surname>
          </string-name>
          ,
          <article-title>and</article-title>
          <string-name>
            <given-names>A.</given-names>
            <surname>Tenschert</surname>
          </string-name>
          , “
          <article-title>Monitoring and assessing energy consumption and CO2 emissions in cloud-based systems</article-title>
          ,” in IEEE SMC, pp.
          <fpage>127</fpage>
          -
          <lpage>132</lpage>
          ,
          <year>2013</year>
          .
        </mixed-citation>
      </ref>
      <ref id="ref4">
        <mixed-citation>
          [4]
          <string-name>
            <given-names>A.</given-names>
            <surname>Verma</surname>
          </string-name>
          , G. Dasgupta,
          <string-name>
            <given-names>T. K.</given-names>
            <surname>Nayak</surname>
          </string-name>
          , P. De, and
          <string-name>
            <given-names>R.</given-names>
            <surname>Kothari</surname>
          </string-name>
          , “
          <article-title>Server workload analysis for power minimization using consolidation,”</article-title>
          <source>in Proceedings of the 2009 conference on USENIX Annual technical conference</source>
          , USENIX'
          <fpage>09</fpage>
          , (Berkeley, CA, USA), pp.
          <fpage>28</fpage>
          -
          <lpage>28</lpage>
          ,
          <string-name>
            <given-names>USENIX</given-names>
            <surname>Association</surname>
          </string-name>
          ,
          <year>2009</year>
          .
        </mixed-citation>
      </ref>
    </ref-list>
  </back>
</article>